HomeMy WebLinkAboutORD 23-036ORDINANCE NO. 23-036 AN ORDINANCE OF THE CITY OF BEAUMONT ADOPTING THE 2021 INTERNATIONAL MECHANICAL CODE, Division 5. Mechanical Code Sec.24.02.201 Adoption There is hereby adopted by the City, for the purpose of establishing rules and regulations for air conditioning, heating and ventilating equipment, refrigeration, ducts and duct systems, piping, incinerators, and electrical requirements for same, that certain Code known as the International Mechanical Code, being particularly the 2021 edition, including Appendix A, of which one (1) copy has been and now is fled in the office of the City Clerk and the same is hereby adopted and incorporated as fully as if set out at length herein, and from the date on which this division shall take effect, the provisions thereof shall be controlling in the construction of air conditioning, heating, and ventilating equipment, refrigeration equipment, ducts and duct systems, piping, incinerators, and the electrical requirements for same, save and except the portions of the International Mechanical Code which are hereby deleted, substituted, modified, or amended as set forth in this division. (Ordinance 78-52, Sec. 1, adopted 5/9/78; Ordinance 89-61, Sec. 1, adopted 8/22/89; Ordinance 96-60, Sec. 1, adopted 10/15/96; Ordinance 03-080, Sec, 9, adopted 10/14/03; 1978 Code, Sec. 6-170; Ordinance 10- 057, Sec. 21, adopted 813/10; Ordinance 17-008, Sec. 9, adopted 217/17) Sec, 24.02.202 Amendments Section 106.6.2 of the International Mechanical Code is hereby amended to read as follows: Section 106,5.2 Fee schedule. See Section 24,01.002, adoption of fee schedule, of the Code of Ordinances of the City of Beaumont. Section 301.7 of the International Mechanical Code is amended to read as follows: Section 301.10 (301.7) Electrical_. All electric connections between fuel -fired appliances, mechanical equipment, etc., and the building wiring shall conform to the National Fire Protection Association (N.F.P.A.-70) and the currently adopted National Electrical Code. Sections 301.10.1 and 301.10.2 are added to read as follows: Section 301.10.1 For new construction, a disconnecting means, one hundred fifteen -volt outlet shall be installed within sight and easy reach in the ungrounded leads of each power circuit to electrically operated components. The disconnecting means shall in no case be installed farther than six (6) feet from the service side of the equipment. Section 301.10.2 For existing construction, disconnecting means (shall be installed) within sight, not more than a fifty (50) foot distance from the equipment, and within easy reach to the ungrounded leads of each power circuit to electrically operated components. Section 306.3 of the International Mechanical Code is amended to read as follows: Section 306.3 Appliances in attics. Attics containing appliances shall be provided with an opening and unobstructed passageway large enough to allow removal of the largest appliance. The passageway shall not be less than thirty (30) inches or seven hundred sixty-two (762) millimeters high and twenty-two (22) inches or five hundred fifty-nine (559) millimeters wide and not more than twenty (20) feet or six thousand ninety-six (6096) millimeters in length measured along the centerline of the passageway from the opening to the appliance. The passageway shall have continuous solid flooring not less than twenty-four (24) inches or six hundred ten (610) millimeters wide. A level service space not less than thirty (30) inches or seven hundred sixty-two (762) millimeters deep and thirty (30) inches or seven hundred sixty-two (762) millimeters wide shall be present at the front or service side of the appliance. The clear access opening dimensions shall be a minimum of twenty (20) inches by thirty (30) inches or five hundred eight (508) millimeters by seven hundred sixty-two (762) millimeters, and large enough to allow removal of the largest appliance. Exceptions: 1. The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening. 2. Where the passageway is unobstructed and not less than six (6) feet (1829 mm) high and twenty-two (22) inches or five hundred fifty-nine (559) millimeters wide for its entire length, the passageway shall be not greater than fifty (50) feet or fifteen thousand two hundred- fifty (15250) millimeters in length. 3. In all Group R occupancies, a pull -down stairway shall be installed for appliance access. (Ordinance 78-52, Sec. 1, adopted 5/9/78; Ordinance 83-40, Sec. 4, adopted 4/19/83; Ordinance 90-16, Secs. 1, 2, adopted 3/13/90; Ordinance 92-80, Sec. 1, adopted 11/24/92; Ordinance 96-60, Sec. 2, adopted 10/15/96; Ordinance 99-46, Sec. 1, adopted 6/29199; Ordinance 03-080, Sec. 9, adopted 10/14/03; 1978 Code, Sec. 6-171; Ordinance 10-057, Sec. 22, adopted 8/3/10; Ordinance 17-008, Sec. 10, adopted 2/7/17) Secs.24.02.203--24.02.250 Reserved That the statement and findings set out in the preamble to this ordinance are hereby in all things approved and adopted. The meeting at which this ordinance was approved was in all things conducted in strict compliance with the Texas Open Meetings Act, Texas Government Code, Chapter 551. PASSED BY THE CITY COUNCIL of the City of Beaumont this the 4th day of April, 2023. 1 - Mayor Robin Mouton -