HomeMy WebLinkAboutPZ2021-455 (02)DATE: April 18,2022
TO: Planning Commission and City Council
FROM: Chris Bootie, Interim City Manager
SUBJECT: To consider a request for a Specific Use Permit to allow a commercial strip center
including a laundromat, retail and office space in a GC-MD-2 (General Commercial —
Multiple -Family Dwelling — 2) District.
P41LE: PZ2021-455
STAFF RE, PORT
Aaron Ward of Faust Engineering and Surveying, Inc., is requesting a Specific Use Permit to,
allow a conimercial strip center including a laundromat, retail and office space at 2855 N. Major
Drive. This property was annexed in 2016 and zoned to GC-MD-2 (General Cornmercial -
Multiple Family Dwelling - 2) in 2018. Existing development on this portion of the west side of
Maj or Drive was existing when the annexation took place.
Mr. Ward states that possible uses may include a laundromat, retail and office space. The site
will include up to twelve (12) lease spaces. All utilities are available along North Major Drive
and the developer states that drainage will be provided by TXDOT (Texas Department of
Transportation).
A six (6) foot wide landscaped strip and a sidewalk will be required along Major Drive.
Staff recommends approval with the following condition:
1. Must meet all requirements by Water Utilities for any water and sanitary sewer
improvements, including any requirements of the City's backflow and/or pre-treatment
programs.
2. Install landscaping to meet City of Beaumont regulations.
3. Aquire TXDOT permission for the sidewalk along Major or construct the sidewalk on
private property.
Please note that final occupancy approval is subject to review and acceptance of submitted plans
and field inspections to verify compliance with applicable codes.
Exhibits are attached.
PUBLIC NOTIFICATION
Notices mailed to property owners 5
Responses in Favor Responses in Opposition
LEGAL DESCRIPTION FOR ORDINANCE PURPOSES
THAT CERTAIN 3.50 acre tract or parcel of land out of the Almanzon Huston Survey,
Abstract No. 33, and being out of the remainder of a called 3 3.5 77 acre tract conveyed to CNA
Rental Management, LLC, as described in Clerk's File Number 2014025117 of the Real
Property Records of Jefferson County, Texas; said 3.50 acre tract being more particularly
described by metes and bounds as follows:
COMMENCING at a 1/2" rebar found in west right-of-way line of North Major Drive, the
southeast corner of a tract conveyed to Beaumont Providence, LP, as described in Clerk's File
Number 2014008926 of the Real Property Records of Jefferson County, Texas and the northeast
corner of a called 2.89 acre tract conveyed to P&N Sandhar Investments, as described in Clerk's
File Number 2021013008 of the Real Property Records of Jefferson County, Texas; said rebar
being the northeast corner of said CNA Rental tract;
THENCE South 02'52'54" East (called South 02'52'54" East) along the west right-of-way line
North Major Drive and the east line of the said P&N Sandhar tract, a distance of 3 89'.73 feet to a
1/2" rebar found and capped "FAUST" for the southeast comer of'said P&N Sandhar tract;
THENCE South 02'52'54" East (called South 02'5254" East) along the west right-of-way line
North Major Drive and the cast line of said CNA Rental tract, a distance of 455.00 feet to a 1/2"
rebar set and capped "FAUST" for the northeast comer of the herein described tract and being
the POINT OF BEGINNING;
THENCE South 02'52'54" East (called South 02'52'54" East) along the west right-of-way line
North Major Drive and the cast line of said CNA Rental tract, a distance of 455.00 feet to a 1/2"
rebar set and capped "FAUST,, for the southeast comer of the herein described tract;
THENCE South 87'07'12" West, a distance of 335.00 feet, to a 1/2" rebar set and capped
"FAUST" for the southwest corner of the herein described tract;
THENCE North 02'52'54" West, a distance of 455.00 feet to a 1/2" rebar set and capped
"FAUST" for the northwest comer of the herein described tract;
THENCE North 87'07'06" East, a distance of 335.00 feet to the POINT OF BEGINNING
and containing 3.50 acres of land, more or less.
ANALYSIS
CONDITIONS FOR APPROVAL OF SPECIFIC USE PERMIT
(SECTION 28-26.E, ZONING ORDINANCE)
Conditions:
Application Application
is in is not in Comments
compliance cojjjEliance Attached
1, That the specific use will be compatible with
and not injurious to the use and enjoyment of
other property, or significantly diminish or impair
property values within the immediate vicinity; x
2. That the establishment of the specific use will
not impede the normal and orderly development
and improvement of surrounding vacant property; x
3. That adequate utilities, access roads, drainage
and other necessary supporting facilities have
been or will be provided; x
4. The design, location and arrangement of all
driveways and parking spaces provides for the
safe and convenient movement of vehicular and
pedestrian traffic without adversely affecting the
general public or adjacent developments; x
5. That adequate nuisance prevention measures
have been or will be taken to prevent or control
offensive odor, fumes, dust, noise and vibration; x
6. That directional lighting will be provided so as
not to disturb or adversely affect neighboring
properties; x
7. That there are sufficient landscaping and
screening to insure harmony and compatibility
with adjacent property; and, x
8. That the proposed use is in accordance with the
Comprehensive Plan. x
GENERAL INFORMATION/PUBLIC UTILITIES
APPLICANT: Aaron Ward
PROPERTY OWNER: Chi -is Truong
LOCATION: 2855 N. Major Drive, Suite A
EXISTING ZONING: GC-MD-2 (General Commercial ---
Multiple-Family Dwelling - 2) District
PROPERTY SIZE:
—3.4 acres
EXISTING LAND USES:
Commercial
FLOOD HAZARD ZONE:
X — Area determined to be outside the 500-
year flood plain
SURROUNDING LAND USES:
SURROUNDING ZONING:
NORTH: Commercial
GC-MD-2 (General Commercial —
Multiple -Family Dwelling - 2) District
EAST: Vacant /Residential
GC-MD-2 and RM-H (Residential
Multiple -Family Dwelling — Highest
Density)
SOUTH: Vacant
GC-MD-2
WEST: Vacant/Rural
GC-MD-2
COMPREHENSIVE PLAN: Neighborhood Growth Unit
STR E E T S: Major Drive — Major Arterial with 13 0' wide
rigl-tt-of-way and —85' pavement width.
DRAINAGE: Open ditch
WATER: 8" & 24" water lines
SANITARY SEWER SERVICE: 54" Sanitary sewer line
PROPERTY OWNERS NOTIFIED WITHIN 2001
WES°T'CHASE PROPERTY HOMEOWNERS
GRAHAM ARCHIE JR
SMITH RONALD G
ZULAG PROPERTIES LLC
CNA RENTAL MANAGEMENT LLC
[61 :f AA1
1 RVA t*1
Case Type:Planning and Zoning
Case Sub Type: Specific Use Permit
Case #: PZ2021-455
Location. 3175 N MAJOR DR, BEAUMONT, TX
Individuals listed on the record,
Applicant
Aaron Ward
5550 Eastex Freeway, Suite 0
Beaumont, TX 77708
Property Owner
Chris Truong (CNA Rental Management LLC)
4410 FOLSOM
Beaumont, TX 77706
Agent
Aaron Ward
5550 Eastex Freeway, Suite 0
Beaumont, TX 77708
Case Type: Planning and Zoning
Case #: PZ2021-455
Case Status: REVIEW
Tag Name- Commercial - Strip Center
Initiated On: 12/2212021 4:09:42PM
Home Phone: 409-813-3410
Work Phone:
Cell Phone: 409-813-3410
E-Mail: aaron@fausteng.com
Home Phone: 409-679-4189
Work Phone:
Cell Phone: 409-679-4189
E-Mail:
Home Phone: 409-813-3410
Work Phone:
Cell Phone: 409-813-3410
E-Mail: aaron@fausteng.com
Page 1 of 2
Printed On: 12130/2021
AUM T
Planning & Community Development
Legal Description TR 2 AB 33 A HOUSTON 25.776AG
(Site will be south adjacent to current
building at 3265 N Major)
Number of Acres 3.37
Proposed Use Commercial strip center
That the specific use will be
The granting of this request will not be injurious to the use and
compatible with and not injurious to
enjoyment of other properties in the area. The parking will provide
the use and enjoyment of other
adequate traffic flow and the entrance was constructed as part of the
property, nor significantly diminish or
original site to the north. Traffic flow will not be adversely altered by
impair property values within the
this permit.
immediate vicinity
That the establishment of the specific
use will not impede the normal and
orderly development and improvement
of surrounding vacant property;
That adequate utilities, access roads,
drainage and other necessary
supporting facilities have been or will
be provided
The design, location and arrangement
of all driveways and parking spaces
provides for the safe and convenient
movement of vehicular and pedestrian
traffic
That adequate nuisance prevention
measures have been or will be taken
to prevent or control offensive odor,
fumes, dust, noise and vibration
That directional lighting will be
provided so as not to disturb or
adversely affect neighboring
properties
That there are sufficient landscaping
and screening to insure harmony and
compatibility with adjacent property
That the proposed use is, in
accordance with the Comprehensive
Plan
Notes:
Case Type: Planning and Zoning
Case 4: PZ2021-455
The granting of this permit will not impede the normal development of
the surrounding area. The neighborhood is being developed with
commercial and residential sites. This specific use request meets
the current trend in this area.
The granting of this permit will not require additional supporting
facilities. Utilities are available along North Major Drive and the
project is presently under construction. It will not be necessary to
extend the utilities to the site. Drainage is provided by TXDOT.
The existing parking facilities will provide for the safe and convenient
movement of traffic within the area and will not adversely affect
vehicular or pedestrian traffic.
The granting of this permit will not create offensive odors, fumes,
dust, noise, or vibration.
Directional lighting will be provided so as not to disturb or adversely
affect neighboring properties.
The landscaping and screening meets the City of Beaumont Zoning
Ordinance requirements and will provide sufficient screening to insure
harmony and compatibility with the adjacent properties
The granting of this permit will be in accordance with the
Comprehensive Plan.
Page 2 of 2
Printed On: 12130/2021
.11-1 AUST'En engineering and Surveying, Inc.
Professional Engineers and Professional Surveyors Telephone (409) 813-3410
E-MAIL ADDRESS INFO@FAUSTENG.COM Fax (409) 813-3484
5550 Eastex Freeway, Suite 0
Beaumont, Texas 77708
Surveying Firm Registration No. 100024-00
Engineering Firm Registration No. 4800
March 23, 2022
City of Beaumont
Planning and Zoning Commission
801 Main Street
Beaumont, Texas 77701
To Whom It May Concern:
Re: Specific Use Permit Application — 2855 North Major Drive, Beaumont
Faust Engineering and Surveying, Inc., is presenting a Specific Use Permit Application for the
property at 2855 North Major Drive, Beaumont, Texas. The site will provide lease spaces with
appurtenances including parking, utilities, and drainage. The owner wants to include a portion of
the lease space as a washeteria (north 4,000 sqft). The Specific Use Permit is being requested for
the washeteria and additional lease space which may include restaurants and professional
services. The site will have a grease trap in the sewer system if required.
In granting the permit, please note the following:
0 The granting of this request will not be injurious to the use and enjoyment of other
properties in the area. The parking will provide adequate traffic flow and the entrance
was constructed as part of the original site to the north. Traffic flow will not be adversely
altered by this permit.
0 The granting of this permit will not impede the normal development of the surrounding
area. The neighborhood is being developed with commercial and residential sites. This
specific use request meets the current trend in this area.
0 The granting of this permit will not require additional supporting facilities. Utilities are
available along North Major Drive. It will not be necessary to extend the utilities to the
site. Drainage is provided by TXDOT.
• The existing parking facilities will provide for the safe and convenient movement of traffic
within the area and will not adversely affect vehicular or pedestrian traffic.
0 The granting of this permit will not create offensive odors, fumes, dust, noise,, or vibration.
Specific Use Permit
.1M
Specific Use Permit
Beaumont, Texas
* Directional lighting will beprovided smasnot todisturb oradversely affect neighboring
propertims.
The landscaping and screening meets the City of Beaumont Zoning Ordinance
requirements and will provide sufficient screening to insure harmony and compatibility
with the adjacent properties
r The granting ufthis permit will beinaccordance with the Comprehensive Plan.
Ifyou have any questions, | may hereached bvtelephone at4O9-813-341O`
For The Firm,
rcl-e� (72't�'
RbhardF. Faust P,E,R.P.LS.
I I , I I I I I- ! �
6vo
is rip
IA ".N.- 'I
12:
i5
6, du 0 Nra 6'R
- I
Me go 0 0 + �-Xw 1B
c
Lt
11-4
Ili
,jy.
Dt
I H.
qv,
-- -- — — — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — -
— — — — — — — — — — —
'Gow m.gZaigs
'Z2021-455: Request for a Specific Use Permit to, allow a commercial strip center
ncluding a laundromat, retail and office space in a GC-MD-2 (General Commercial —
Multiple -Family Dwelling — 2) District.
kpplicant: Aaron Ward of Faust Engineering and Surveying, Inc.
,ocation: 2855 N. Major Drive 0 100 200 300 400
1 1 1 1 1 1 Feet