DATE: January 23, 2002
TO: Planning Commission and City Council
FROM: Stephen C. Richardson, Planning Manager
SUBJECT: Request for a zone change from RM-H (Residential Multiple Family Dwelling -Highest
Density) District to GC -MD (General Commercial -Multiple Family Dwelling) District
and a specific use permit to allow a climate -controlled self -storage facility.
FILE: 1598-Z/P
STAFF REPORT
The Planning Manager recommends approval of the zone change from RM-H to GC -MD and
the specific use permit to allow a climate -controlled self -storage facility subject to the gating
of the entrance on Byron Street.
The applicant proposes to construct a 60,000 sq. ft. climate -controlled self -storage facility on
4.5 acres located between Dowlen Road and Byron Street. The proposed building will be of
pre-engineered construction.
The applicant states that there will be typically 8-10 persons per day visiting the facility.
Access to the property is shown as being on both Dowlen and Byron. The Traffic Manager
recommends that the Byron Street drive be gated and used for emergency purposes only. This
would direct all the traffic to Dowlen. Byron is a narrow local street with mostly residential
uses. The shopping center north of the subject property does have one driveway on Byron, just
south of Calder.
Exhibits are attached.
PUBLIC NOTIFICATION
Notices mailed to property owners 64
Responses in Favor . Responses in Opposition
LEGAL DESCRIPTION FOR ORDINANCE PURPOSES
Being Tracts 104B, 214,214A and 214B, C. Williams Survey, Abstract A-59, City of
Beaumont, Jefferson County, Texas, containing 4.5 acres, more or less.
Fittz & Shipman
—INC
December 28, 2001
Mr. Steve Richardson, Dir, Planning
City of Beaumont
P. O. Box 3287
Beaumont, Texas 77704
Re: Access Self Storage, Climate Controlled Building
Dowlen Road @ Railroad Overpass
Consulting Engineers and Land Surve.vot-s
Ronald D. Fift, P.9., R.P.L.S. (1948.1987)
Terry Shipman, P.E., President
John Holm, P,E., L.S_ Vice -President
We Value I U
LAMAR UNIVERSITY
FS Proj. No. 01143
Submitted for your review is an application for Zoning Change and Specific Use Permit for a site
located on the west side of Dowlen Road immediately north of the railroad overpass. It is proposed that
the site be developed for a climate controlled storage facility. Zoning is proposed to be changed from
present RM-H zoning to GC -MD.
1 The proposed climate controlled storage facility will be a high quality pre-engineered building
which will be compatible with other commercial developments along Dowlen Road both north and
south of the proposed facility. The sign for the facility will be 6 ft x 8 ft and will be roof mounted.
2. The establishment of this specific will not impede the normal and orderly development and
improvement of the surrounding properties
3. Adequate utilities, access roads, drainage and other necessary supporting facilities (telephone,
gas, electric) are available to the site.
4. The proposed climate controlled storage facility creates a low volume of vehicular traffic. Daily
logs kept at other facilities by the Owner indicate that there are typically 8-10 persons per day
visiting the facility. In addition, the design and location of the proposed driveways and parking
spaces will provide for safe and convenient movement of vehicular and pedestrian traffic with
adversely affecting the general public or adjacent development.
5. Adequate nuisance prevention measures will be taken to prevent or control offensive odor,
fumes, dust, noise and vibration.
6. Directional lighting proposed will be installed so as not to disturb or adversely affect neighboring
properties.
7. Landscaping and screening will be provided in accordance with City of Beaumont ordinances,
8, This proposed use presents no conflicts with or deviations from the City of Beaumont
Comprehensive Plan.
Should you have any questions, please feel free to contact me.
Sincerely,
F IT TZ & SHIPMA N, INC.
by: onald R. Ki gi" P.
DRK/drk 7
For the Firm
11 43LT01
1405 Cornerstone Court - Beaumont, Texas 77706 * (409) 832-7238 - fax (409) 832-7303
INC
Consulting Engineers and Land Surveyors
Ronald 0. Fittz, PE., R.P.L.S. (1948-1987)
Terry Shipman, P.E., President
John Holm, P.E., L.S., Vice -President
January 17, 2002
Mr. Steve Richardson, Dir. Planning We Value
City of Beaumont LAMAR UNIVERSITY
P. 0, Box 3287
Beaumont, Texas 77704
Re: Access Self Storage, Climate Controlled Building FS Proj. No. 01143
Dowlen Road @ Railroad Overpass
Dear Mr, Richardson:
Submitted for your review is a revised site plan for the proposed Access Self Storage facility located on
the west side of Dowlen Road immediately north of the railroad overpass. Information has been added
indicating proposed drainage and landscaping..
All drainage on the site will be directed to drainage inlets within the parking lot which will convey storm
water via underground storm sewer eastward to connect to the existing 36" storm sewer located along the
west side of the Dowlen Road overpass. This 36" storm sewer conveys storm water southward to the
existing drainage channel located south of the Union Pacific Railroad tracks.
The site presently contains numerous trees which will be preserved within the islands and non -paved
areas to meet the requirement of the City of Beaumont Landscape Ordinance,
As indicated previously, the amount of daily traffic to the site is expected to be 8-10 vehicles per day. In
addition, the driveway entrance on Dowlen Road is expected to carry the bulk of the traffic. The median
of Dowlen Road is directly in front of the driveway, therefore vehicles must enter the facility heading
southbound on Dowlen or turn right on Dowlen Road to exit the facility, There should be no vehicles
making conflicting left turns on Dowlen Road.
Should you have any questions, please feel free to contact me.
Sincerely,
FITTZ & SHIPMAN, INC.
by: Donald R. ��g7l[E
For the Firm y
DRKJdrk
1143LT04
ffm
7 2 () "U "
' ")
1405 Cornerstone Court - Beaumont, Texas 77706 - (409) 832-7238 . fax (409) 832-7303
Li7 aY 'kY 2;
ry
FILE 1598-ZIP: Request for a zone change from RM-H (Residential Multiple Family NORTH
Dwelling - High Density) to GC -MD (General Commercial - Multiple Family
Dwelling) district with a specific use permit to allow a climate controlled mini -storage ,� A,
facility. SCa►1 E
Location. Dowlen Rd. @ the Railroad overpass 1"=2001 Cr
Applicant: Fittz & Shipman, Inc. for Scott Monroe
st .aY� sit �o-ryy «t rsi Y�ict:
toll
w �t
1V1 H
10SG
too
layL
r
t
J
8 .S
C
L to may,
U roaA b1
qy , 1l z
`s97
�o N I ?y 4 /d d. 4/ M5 4 14
RS
Ibt 1 q' 4
3
1 r
I T tl 6
2
y M w
00$ I
WESTWOOD BLVD.
W W1
AIDDITICINO
g t i s
R
r, #�_Om ■
FCC:
'
sill
PROP. 17
300
MXAUK OW4
ko
tak
PROPOSED CLIMATE
CONTROLLED STORAGE
0 11
II
Q)
tll
C
0
0
CD
EVONG
TREES
FUTURE
I
DEVELOPMENT
it
— — — — — — — — — — — — — — — — —
— — — — — — — — — —
— — -
IUU
SCAU: V. 4V
Missouri Pacific
Railroad
FIrrZ & SHIPMAN
:EE5 m '= 3= 3--
-A"
—�;
ppwta NAWK: MXTU WTW-WK Bv,tmW5
DOW= ROAD
mat W,
W"
w0movr. Imm
0143-DOO
ANALYSIS
CONDITIONS FOR APPROVAL OF SPECIFIC USE PERMIT
(SECTION 30-26.E. ZONING ORDINANCE
Application Application
is in is not in Comments
Compliance Compliance Attached
CONDITIONS:
1. That the specific use will be
compatible with and not injurious
to the use and enjoyment of other
property, nor significantly diminish
or impair property values within
the immediate vicinity; x
2. That the establishment of the
specific use will not impede the
normal and orderly development and
improvement of surrounding vacant
property; x
3. That adequate utilities, access
roads, drainage and other necessary
supporting facilities have been or
will be provided; x x
4. The design, location and arrangement
of all driveways and parking spaces
provides for the safe and convenient
movement of vehicular and pedestrian
traffic without adversely affecting
the general public or adjacent
developments; x x
S. That adequate nuisance prevention
measures have been or will be taken
to prevent or control offensive odor,
fumes, dust, noise and vibration; x
6. That directional lighting will be
provided so as not to disturb or
adversely affect neighboring properties; x
7. That there are sufficient landscaping
and screening to insure harmony and
compatibility with adjacent property; and x
8. That the proposed use is in accordance
with the Comprehensive Plan. x
ANALYSIS continued
This application is in compliance with the eight conditions necessary for approval. Comments
on Conditions 3 and 4 follow:
3) Drainage of the property will be directed to drainage inlets within the parking lot which
will convey storm water via underground storm sewers eastward to connect to the
existing 36" storm sewer located along the west side of the Dowlen Road overpass.
4) The Traffic Manager recommends that the Byron Street driveway be gated and used for
emergency purposes only. The Planning Manager has made that a part of the
recommendation.
GENERAL INFORMATION/PUBLIC UTILITIES
APPLICANT: Fittz & Shipman, Inc.
PROPERTY OWNER: Scott Monroe, Keith McCoy and Gary Hidalgo
LOCATION: West side of the Dowlen Road railroad
overpass
LEGAL DESCRIPTION: Tracts 104B, 214, 214A & 21413, C. Williams
Survey, Abstract 59
EXISTING ZONING: RM-H (Residential Multiple Family -Highest
Density) District
PROPERTY SIZE: 4.5 acres, more or less
EXISTING LAND USES: Vacant and a house
FLOOD HAZARD ZONE: "C" - Minimal flooding
SURROUNDING LAND USES: SURROUNDING ZONING:
NORTH: Commercial NSC (Neighborhood Shopping Center) District
EAST: Dowlen Road and residential RS (Residential Single Family Dwelling) District
SOUTH: Railroad and commercial LI (Light Industrial) District
WEST: Residential and vacant RM-H (Residential Multiple Family -Highest Density) District
COMPREHENSIVE PLAN: Community Center
GENERAL INFORMATION/PUBLIC UTILITIES continued
OTHER PHYSICAL
FEATURES: None
STREETS: Dowlen Road - Major arterial with a I 00'right-
of-way and 4 lanes of traffic; Byrou Street -
local street with a 50' right-of-way and a 14'
pavement
DRAINAGE: Dowlen Road - 36" storm sewer
Byron St. - open ditch
WATER: Dowlen Road - 6" water
Byron St. - 2" water
SANITARY SEWER
SERVICE: Dowlen Road - 30" sanitary sewer
Byron St, - 8" sanitary sewer
FIRE PROTECTION: Fire protection is provided by Station #6, 1880
Major Dr,
ADEQUACY
OF SERVICE: Set -vices are adequate.