HomeMy WebLinkAbout1551-ZPDATE: March 19,2001
TO: Planning Commission and City Council
FROM: Stephen C. Richardson, Planning Manager
SUBJECT: Request for a zone change from RS (Residential Single Family Dwelling) and RM-H
(Residential Multiple Family Dwelling -Highest Density) to GC-MD-2 (General
Conimercial-Multiple Family Dwelling-2) District and a specific use permit to allow
a personal storage warehouse at 1655 S. Major Drive.
FILE: 1551-Z/P
Rvirn A -Ma Sze] jnj
The Planning Manager recommends approval of the zoning change to GC-MD-2 and
approval of the specific use permit. The application is in compliance with the eight
conditions necessary for approval.
The applicant proposes to build an air conditioned and heated brick, masonry and metal
40,000 square foot warehouse. All storage units are to be located within the building. This
is a self storage facility. Landscaping, trees and screening fences will be installed. An
irrigation system will provide water for the landscaping. The applicant will also install
wrought iron fencing in addition to the required screening. The warehouse will have offices
and restrooms.
Lots 12-14 are zoned RM-H. Lots 15 and 16 are zoned RS. The GC-MD-2 district requires
a specific use permit.
Exhibits are attached.
PUBLIC NOTIFICATION
Notices mailed to property owners 56
Responses in Favor 10 . Responses in Opposition
LEGAL DESCRIPTION FOR ORDINANCE PURPOSES
Being Lots 12, 13, 14, 15 and 16, Block "A", Mayfair Addition, City of Beaumont, Jefferson
County, Texas, containing 3.6 acres, more or less.
FILE 1551-Z/P: Zone change request from KS (Residential Single Family Dwelling) NORTH
and RM-H (Residential Multiple Family Dwelling - High Density) to GC-MD-2
(General Commercial - Multiple Family Dwelling - 2) District and an application frolra A
specific use permit to allow a personal storage warehouse. SCALE
Location: 1655 S. Major Drive (FM 364) 1 11=200,
Applicant: Eugene R. Allen
FRAZIER DR.
46W '70 4% 0--
i M
I.
MEN
0 1 J 0 0
o
-10
E, !
I
6
•
0
Is
E. R. Allen
10494 Bonwell Loop
Kountze, TX 77625-9719
February 22, 2001
Planning Commission and City Council
Planning Division, Room 205
Beaumont, TX 77701
RE: Application for Specific Use Permits
1655 South Major Drive
Gentlemen:
I have enclosed the Application for Amendment of the Zoning Ordinance, Specific Use Permit
Application, along with ten (10) copies of my proposed site and elevation plans.
As shown on my Site Plan, I propose to build a 40,000 SF Storage Facility to house individuals'
personal property. This building will be constructed in strict accordance with City of Beaumont
Building Codes and requirements.
This building will have offices and restroom in front area and the remainder of the building will be
partitioned off in storage areas, using metal studs and panels. The entire building will be air
conditioned and heated for climate control.
I plan to have a very attractive front on Major Drive, by using a combination of brick masonry and
metal wall panels on the building and drive through canopy and on each side of the building, I will
use some wrought iron fencing with brick masonry piers.
The landscaping in front, along South Major Drive will consist of small trees, bushes, plants and
ground cover.
After the site has been cleared, I plan to leave trees for a buffer zone on the north and east property
lines, as well as the additional new trees as called for, which will add to the beauty of the site. I
further plan to raise the existing grade elevation approximately 18" to 24" by adding additional fill
material.
Drainage of this site will be accomplished by sloping earth and paving towards Major Drive, where
there is presently very good drainage. I will need to install some swales around property to assure
that water from this property does not drain on to surrounding landowners.
February 22, 2001
Page Two
I plan to have one (1) building identification sign in front of the building which will not exceed 50
sq. ft in size and 35 ft. in height. We also will have,some signage attached to the metal panels in
front wall of building.
Parking will be as shown on site plan as well as the required wood fencing. We also will install an
irrigation system for our landscaping on this project.
On the reverse side of the Specific Use Permit Application, you have a listing of eight (8)
requirements that must be met and I feel that my plans will certainly comply with all eight (8) of
these requirements.
I feel very strongly that given the opportunity to construct this facility, that it will greatly enhance
the beauty and quality of this location and one that we can all be proud of.
I would like to thank the Planning Commission for this opportunity to submit for this Specific Use
Permit and trust that it will meet with your approval.
Yours very truly,
E. R. Allen
enclosures
�M1JNVWh � t
"'--. —
�
/Xa
r
�TNiW- 1 'Al MINI
o � �
no
.14/11
F
r
»
4
— —
1
d
s 77
l
r t/1
f i��
uj
I ll i
!f�
77
!
�F' JI iQ Il�i Ili li (�
Q
i I I I 1-7
I "
.1
110
MINN- CL
LLJ
i
f
I
i
tF
� ar .rw JiA il� 1 d15 �sn
I
/ u "y
� 0
H18ON
``•. x. 0311VD
x
on
b
2i
Lii
>
ry
. . ..... ..... .
ry
0
0
Z
LLJ
(XVIN (>)
0 6
LLJ
_j
LLJ
_77=
0
777
0
V)
z
0
<
>
LU
li
IT
ANALYSIS
CONDITIONS FOR APPROVAL OF SPECIFIC USE PERMIT
(SECTION 30-26.E, ZONING ORDINANCE,
[01001011110303
1. That the specific use will be
compatible with and not injurious
to the use and enjoyment of other
property, nor significantly diminish
or impair property values within
the immediate vicinity;
2. That the establishment of the
specific use will not impede the
normal and orderly development and
improvement of surrounding vacant
property;
3. That adequate utilities, access
roads, drainage and other necessary
supporting facilities have been or
will be provided;
4. The design, location and arrangement
of all driveways and parking spaces
provides for the safe and convenient
movement of vehicular and pedestrian
traffic without adversely affecting
the general public or adjacent
developments;
5. That adequate nuisance prevention
measures have been or will be taken
to prevent or control offensive odor,
fumes, dust, noise and vibration;
6. That directional lighting will be
provided so as not to disturb or
adversely affect neighboring properties;
7. That there are sufficient landscaping
and screening to insure harmony and
compatibility with adjacent property; and
8. That the proposed use is in accordance
with the Comprehensive Plan.
Application
is in
Compliance
...........
x
Application
is not in Commet-ts
Compliance Attached
ANALYSIS continued
This application is in compliance with the eight conditions necessary for approval.
Comments on items I and 3 follow:
1 This property, containing 3.6 acres is now vacant. There is a vacant 100' x 318' tract
to the north toward College Street however, there are various commercial uses,
contractors and offices to the north, also. Land to the east fronting Avalon is
developed residential but the lots are 100 feet wide by 318 feet deep. The eleven acre
property across the street is zoned RM-M and is vacant. Lots to the immediate south
are vacant. The design and use of the proposed building will not impair property
values in the vicinity and will be compatible with the neighborhood.
3. Approval of detailed site drainage plans must be approved by the City Engineer and
TxDot. Applicant plans to raise the existing grade 18" to 24" with fill.
GENERAL INFORMATION/PUBLIC UTILITIES
APPLICANT:
9MKWK*JWJA9
Eugene R. Allen
L. M. And Bonnie Paul
Prospective buyer
1655 S. Major Drive (FM 3 64)
EXISTING ZONING: RS (Residential Single Family Dwelling) and
RM-H (Residential Multiple Family
Dwelling -Highest Density) District
Wrialualk'a
EXISTING LAND USES:
SURROUNDING LAND USES:
NORTH: Vacant tract, businesses
EAST: Residences on 7/10 acre tracts
SOUTH: Vacant tract
WEST: Vacant pasture
3.6 acres
"A" - (100 year)
Vacant
SURROUNDING ZONING:
RM-H and GC -MD
RS
RS
RM-M
GENERAL INFORMATION/PUBLIC UTILITIES continued
COMPREHENSIVE PLAN: Stable Area
OTHER PHYSICAL
FEATURES: None
STREETS: S. Major
jor Drive (FM 364) in this area has a
160' wide right-of-way and an approximate
pavement width of 50' to 60'. The state has
future plans to construct an overpass at Major
and College (U. S. Hwy. 90) and has already
purchased additional right-of-way on the west
side of S. Major.
DRAINAGE: Surface and street side ditches.
WATER: There are 3" and 6" water lines in the highway
right-of-way.
SANITARY SEWER There is an 8" sanitary sewer in the highway
SERVICE: right-of-way.
FIRE PROTECTION: Fire protection is provided by Station #6,
1880 Major (new station).
ADEQUACY
OF SERVICE: Existing services are adequate.