Loading...
HomeMy WebLinkAboutPB 408.01B NEW 02-2017_Firefighter Air Consumption Assessment408.01 Firefighter Air Consumption Assessment Discipline: Fitness Hb Effective: 2/5/2017 f .H.G Revised: Replaces. I. Objective The firefighter shall perform an air consumption assessment wearing full PPE with SCBA while on breathing air. II. Preparation & Equipment A. SCBA B. Face Piece C. PPE D. Air Consumption Course with Equipment E. Stop Watch F. Medical Bag G. AED III. Instructions — Procedures for Achieving the Objective While wearing your full PPE including SCBA, mask and while on breathing air, you will perform the Firefighter Air Consumption Assessment. You will perform the events included in the Air Consumption Assessment in order until one of the following occurs: Your SCBA low pressure alarm sounds You indicate that you are too physically exhausted to continue You experience physical symptoms causing you to feel that you are unable to continue IMPORTANT SAFETY CONSIDERATION: If you feel faint, dizzy, have chest pain or experience other physical symptoms that are not normal for you, stop the assessment and tell the Evaluator. You will begin on my instruction to start. The assessment will end when your low pressure alarm has sounded, you are too physically exhausted to continue, or you experience symptoms and feel you are unable to continue. Do you understand these instructions? IV. Examiner's Note The firefighter will be allowed to review the performance steps prior to the assessment. V. Reference Sources A. Gagliano, M., Phillips, C., Jose, P., et al., Air Management in the Fire Service, I st edition, Penwell: Tulsa, OK, 2008. B. National Fire Protection Association, NFPA 1582 -Standard on Comprehensive Occupational Medical Program for Fire Departments, NFPA: Quincy, MA, 2013. C. Schaeffer, B. Knows the Rules, Fire Rescue, 2010, (28), 8, pp. 80-83. D. Sendelbach, T., SCBA Endurance for Fireground Survival, in www.TES2training.com, accessed Feb. 17, 2013 from www.testraining.com/handouts/SCBA Endurance.pdf. PB 408.01B—Firefighter Air Consumption Assessment Page 2 of 4 408.01 B—Firefighter Air Consumption Assessment Discipline: Fitness Name: Officer #: Evaluator: Officer #: Date: Location: Event 1: High Rise Pack Carry At the signal to begin the evolution, the firefighter picks up and shoulders one 50 foot section of a 1.75" high rise pack and carries it to the top floor of the drill tower, and then drops the hose in a designated area. Event 2: Hose Hoist From the top floor of the drill tower standing in a designated area the firefighter pulls a rope in a hand -over -hand fashion to hoist one 50 foot section of 2.5" hose over the balcony and places it on the floor in the designated area. The firefighter then proceeds down the stairs and outside, walking to the forcible entry prop. Event 3: Force Entry The firefighter utilizes a 10 pound sledgehammer to hit the forcible entry prop until the buzzer sounds. After the buzzer sounds the firefighter places the sledgehammer in the designated area and advances to the hose advance event. Event 4: Hose Advance The firefighter walks to a charged section of 1.75 inch hose, picks up the nozzle and places it over his/her shoulder, then drags the hose 100 feet until the nozzle passes a line marked by traffic cones. Once the nozzle passes the line the firefighter opens the nozzle to show water. The nozzle is then closed and is placed on the ground. If the nozzle is not closed before it touches the ground the participant must go back and shut down the nozzle. The participant advances to the victim rescue event. Event 5: Victim Rescue The firefighter stands at the manikins head, and grabs the drag harness with both hands. The firefighter then walks backwards, moving the manikin 100 feet, passing a line marked with traffic cones. If the firefighter looses his/her grip, falls, PB 408.01B—Firefighter Air Consumption Assessment Page 3 of 4 trips etc., he/she will reset his/her grip and continue until the manikin crosses the 100 foot mark. Repeat Events 1-5: Once the firefighter drags the manikin across the 100 foot mark, he/she will walk back to Event 1 and start the evolution over. He/she will continue until the low pressure alarm activates, or he/she is too physically exhausted, or has symptoms and is unable to continue. At this time the assessment will conclude and the time will be documented. The firefighter will proceed to the rest and rehabilitation area, where his/her condition will be monitored for a minimum of 20 minutes post -assessment. Start Time Finish Time Total Time Pre -Test Vitals Post -Test Vitals 10 Min Post -Test 20 Min Post -Test BP: BP: BP: BP: Pulse: Pulse: Pulse : Pulse: Resp: Resp: Resp: Resp: Comments: PB 408.01 B—Firefighter Air Consumption Assessment Page 4 of 4