Loading...
HomeMy WebLinkAboutPB 407.06L NEW 6-2009PPPEEERRRFFFOOORRRMMMAAANNNCCCEEE BBBEEENNNCCCHHHMMMAAARRRKKKSSS 404040407777.0.0.0.06666LLLL Low Pressure Regulator Replacement (Cylinder psi Low Pressure Regulator Replacement (Cylinder psi Low Pressure Regulator Replacement (Cylinder psi Low Pressure Regulator Replacement (Cylinder psi belowbelowbelowbelow 1000) 1000) 1000) 1000) Anne Huff,Anne Huff,Anne Huff,Anne Huff, Fire Chief Fire Chief Fire Chief Fire Chief Beaumont Fire-Rescue Services Discipline:Discipline:Discipline:Discipline: R.I.G.R.I.G.R.I.G.R.I.G. Effective:Effective:Effective:Effective: 02020202////10101010////2002002002009999 Revised:Revised:Revised:Revised: Replaces:Replaces:Replaces:Replaces: I. I. I. I. ObjectiveObjectiveObjectiveObjective Wearing full personnel protective equipment, the examinee shall properly secure and supply the downed firefighter with supplied air from the RIG pack by changing out the low pressure hose. II. II. II. II. Instructions Instructions Instructions Instructions –––– Procedur Procedur Procedur Procedures for Achieving the Objectivees for Achieving the Objectivees for Achieving the Objectivees for Achieving the Objective With the downed firefighter lying on the ground, you shall correctly secure and supply air to the downed firefighter by replacing their low pressure regulator with the RIG pack low pressure regulator using proper methods and procedures. The cylinder psi will be below 1000. The skill will begin on my instruction to start. The skill will end when all steps have been met and the examinee successfully supplies air to the downed firefighter. Do you understand these instructions? III. III. III. III. Examiner’s NoteExaminer’s NoteExaminer’s NoteExaminer’s Note The examinee will not be able to review the performance steps prior to testing. The downed firefighter shall be in place before admitting the examinee into the test area. The examinee will not be able to touch the SCBA or the RIG pack prior to the start of the examination. IV. IV. IV. IV. Preparation & EquipmentPreparation & EquipmentPreparation & EquipmentPreparation & Equipment A. Person to act as the downed firefighter B. Personnel protective equipment C. SCBA D. RIG pack V. V. V. V. Reference SourcesReference SourcesReference SourcesReference Sources A. NFPA 1407, Training Fire Service Rapid Intervention Crews. B. NFPA 1404, Fire Service Respiratory Protection Training. PB 407.06L – Low Pressure Regulator Replacement (cylinder psi below 1000) Page 2 of 2 407.06L – Low Pressure Regulator Replacement (cylinder psi below 1000) Discipline: R.I.G. Name: Officer #: Evaluator: Officer #: Date: Location: If the firefighter:If the firefighter:If the firefighter:If the firefighter: ((((No partial points given)No partial points given)No partial points given)No partial points given) a) Removes low pressure regulator from RIG bag.......................................1.0 _____ b) Connects RIG low pressure regulator to proper connection.....................P/FP/FP/FP/F _____ c) Opens RIG bag SCBA cylinder valve......................................................P/FP/FP/FP/F _____ d) Replaces downed firefighter’s low pressure regulator with the RIG bag low pressure regulator.................................................................................1.0 _____ e) Verifies air flow.....................................................................................P/FP/FP/FP/F _____ Note: Attach this page to the first. Points Points Points Points PossiblePossiblePossiblePossible Passing Passing Passing Passing ScoreScoreScoreScore AttemptAttemptAttemptAttempt Performance RatingPerformance RatingPerformance RatingPerformance Rating (Points)(Points)(Points)(Points) PASSPASSPASSPASS FAILFAILFAILFAIL First Second 2 2 Third