I. I. I. I. ObjectiveObjectiveObjectiveObjective
Wearing full personnel protective equipment, the examinee shall properly secure and
supply the downed firefighter with supplied air from the RIG pack by changing out the low
pressure hose.
II. II. II. II. Instructions Instructions Instructions Instructions –––– Procedur Procedur Procedur Procedures for Achieving the Objectivees for Achieving the Objectivees for Achieving the Objectivees for Achieving the Objective
With the downed firefighter lying on the ground, you shall correctly secure and supply air
to the downed firefighter by replacing their low pressure regulator with the RIG pack low
pressure regulator using proper methods and procedures. The cylinder psi will be below 1000.
The skill will begin on my instruction to start. The skill will end when all steps have been met
and the examinee successfully supplies air to the downed firefighter. Do you understand these
instructions?
III. III. III. III. Examiner’s NoteExaminer’s NoteExaminer’s NoteExaminer’s Note
The examinee will not be able to review the performance steps prior to testing. The
downed firefighter shall be in place before admitting the examinee into the test area. The
examinee will not be able to touch the SCBA or the RIG pack prior to the start of the
examination.
IV. IV. IV. IV. Preparation & EquipmentPreparation & EquipmentPreparation & EquipmentPreparation & Equipment
A. Person to act as the downed firefighter
B. Personnel protective equipment
C. SCBA
D. RIG pack
V. V. V. V. Reference SourcesReference SourcesReference SourcesReference Sources
A. NFPA 1407, Training Fire Service Rapid Intervention Crews.
B. NFPA 1404, Fire Service Respiratory Protection Training.
PB 407.06L – Low Pressure Regulator Replacement (cylinder psi below 1000) Page 2 of 2
407.06L – Low Pressure Regulator Replacement (cylinder psi
below 1000)
Discipline: R.I.G.
Name: Officer #:
Evaluator: Officer #:
Date: Location:
If the firefighter:If the firefighter:If the firefighter:If the firefighter: ((((No partial points given)No partial points given)No partial points given)No partial points given)
a) Removes low pressure regulator from RIG bag.......................................1.0 _____
b) Connects RIG low pressure regulator to proper connection.....................P/FP/FP/FP/F _____
c) Opens RIG bag SCBA cylinder valve......................................................P/FP/FP/FP/F _____
d) Replaces downed firefighter’s low pressure regulator with the RIG bag low
pressure regulator.................................................................................1.0 _____
e) Verifies air flow.....................................................................................P/FP/FP/FP/F _____
Note: Attach this page to the first.
Points Points Points Points
PossiblePossiblePossiblePossible
Passing Passing Passing Passing
ScoreScoreScoreScore
AttemptAttemptAttemptAttempt
Performance RatingPerformance RatingPerformance RatingPerformance Rating
(Points)(Points)(Points)(Points)
PASSPASSPASSPASS
FAILFAILFAILFAIL
First
Second 2 2
Third