Loading...
HomeMy WebLinkAboutPB 404.03M NEW 12-5-2010PPPEEERRRFFFOOORRRMMMAAANNNCCCEEE BBBEEENNNCCCHHHMMMAAARRRKKKSSS 404.03404.03404.03404.03MMMM ---- Transfer Valve Operation (Aerial Fire Pump)Transfer Valve Operation (Aerial Fire Pump)Transfer Valve Operation (Aerial Fire Pump)Transfer Valve Operation (Aerial Fire Pump) Anne Huff,Anne Huff,Anne Huff,Anne Huff, Fire ChiefFire ChiefFire ChiefFire Chief Beaumont Fire-Rescue Services Discipline:Discipline:Discipline:Discipline: DDDDriverriverriverriver/O/O/O/Operatorperatorperatorperator Effective:Effective:Effective:Effective: 12/5/201012/5/201012/5/201012/5/2010 Revised:Revised:Revised:Revised: Replaces:Replaces:Replaces:Replaces: I. I. I. I. ObjectiveObjectiveObjectiveObjective The Driver/Operator, given a fire department aerial apparatus with a multi-stage pump, shall demonstrate the operation of the volume/pressure transfer value under actual pumping conditions. II. II. II. II. Instructions Instructions Instructions Instructions –––– ProcedProcedProcedProcedures for Achieving the Objectiveures for Achieving the Objectiveures for Achieving the Objectiveures for Achieving the Objective Given a fire department aerial apparatus with a multi-stage pump, you shall demonstrate the operation of the volume/pressure transfer valve under actual pumping conditions. The skill will end when you state to the examiner that you have completed all the identified steps. Do you understand these instructions? III. III. III. III. Examiner’s NoteExaminer’s NoteExaminer’s NoteExaminer’s Note The Driver/Operator will be given a condition that requires him/her to start in the series or pressure position and then change over to the parallel or volume position. The Driver/Operator will not be allowed to review the performance steps at the time of testing. IV. IV. IV. IV. Preparation & EquipmentPreparation & EquipmentPreparation & EquipmentPreparation & Equipment A. Fire department aerial apparatus with a multi-stage pump V. V. V. V. RRRReference Sourceseference Sourceseference Sourceseference Sources A. IFSTA, Aerial Apparatus Driver/Operator Handbook, 2nd edition B. Manufacturer’s Operating Manual C. NFPA 1002, 3-1.1, 3-2.1 PB 404.03M – Transfer Valve Operation (Aerial Fire Pump) Page 2 of 2 404.03M – Transfer Valve Operation (Aerial Fire Pump) Discipline: D/O Name:Name:Name:Name: Officer #:Officer #:Officer #:Officer #: Evaluator:Evaluator:Evaluator:Evaluator: Officer #:Officer #:Officer #:Officer #: DatDatDatDate:e:e:e: Unit:Unit:Unit:Unit: Location:Location:Location:Location: If the If the If the If the DDDDriver/river/river/river/OOOOperatorperatorperatorperator: : : : (No partial points given) A. Operates the pump in the series (pressure) position………………………..2.0_____ B. Verbally states to the examiner when or why the pump would need to be transferred from the series (pressure) position to the parallel (volume) position……………………………………………………………….1.0_____ C. Operates the transfer valve manually or electronically shifting the pump from the series (pressure) position to the parallel position at idle pressure………………………………………………………………….P/FP/FP/FP/F_____ D. Operates the pump in the parallel (volume) position……………………….2.0_____ Points Points Points Points PossiblePossiblePossiblePossible Passing Passing Passing Passing ScoreScoreScoreScore AttemptAttemptAttemptAttempt Performance RatingPerformance RatingPerformance RatingPerformance Rating (Points)(Points)(Points)(Points) PASSPASSPASSPASS FAILFAILFAILFAIL 5 4 First Second Third