Loading...
HomeMy WebLinkAboutPB 404.02I REVISED 10-2009PPPEEERRRFFFOOORRRMMMAAANNNCCCEEE BBBEEENNNCCCHHHMMMAAARRRKKKSSS 404404404404.0.0.0.02I 2I 2I 2I Relay Pumping From a Pressurized SourceRelay Pumping From a Pressurized SourceRelay Pumping From a Pressurized SourceRelay Pumping From a Pressurized Source Anne Huff, Fire ChiefAnne Huff, Fire ChiefAnne Huff, Fire ChiefAnne Huff, Fire Chief Beaumont Fire-Rescue Services Discipline:Discipline:Discipline:Discipline: D/OD/OD/OD/O Effective:Effective:Effective:Effective: 6666////5/2005/2005/2005/2002222 Revised:Revised:Revised:Revised: 10/5/200910/5/200910/5/200910/5/2009 Replaces:Replaces:Replaces:Replaces: Driver Benchmark 215 Driver Benchmark 215 Driver Benchmark 215 Driver Benchmark 215 I. I. I. I. ObjectiveObjectiveObjectiveObjective Pump a supply line of 2-1/2 inches or larger, given a relay pumping evolution the length and size of the line and the desired flow and intake pressure, so that the correct pressure and flow are provided to the next pumper in the relay. II. II. II. II. Instructions Instructions Instructions Instructions –––– Procedures for Achieving the ObjectiveProcedures for Achieving the ObjectiveProcedures for Achieving the ObjectiveProcedures for Achieving the Objective Given a fire department pumper as the source pumper, the Driver/Operator shall properly position and set up the apparatus to pump in relay to a designated relay apparatus. III. III. III. III. Examiner’s NoteExaminer’s NoteExaminer’s NoteExaminer’s Note The Driver/Operator will not be allowed to review the performance steps at the time of testing. The receiving pumper needs 350 GPM. The pumpers must be a minimum of 300 feet apart. IV. IV. IV. IV. Preparation & EquipmentPreparation & EquipmentPreparation & EquipmentPreparation & Equipment A. Two fire department pumpers B. Minimum of 300 ft. of hose, 2-½ inches in diameter or larger C. Hydrant V. V. V. V. Reference SourcesReference SourcesReference SourcesReference Sources A. IFSTA, Pumping Apparatus Driver/Operator Handbook, 2nd Edition B. TCFP, Performance Standard, Section 700-5.2 C. NFPA 1002, 5.2.1, 5.2.2, 5.2.4 PB 404.02I – Relay Pumping from a Pressurized Source Page 2 of 2 404.02I – Relay Pumping From a Pressurized SourceRelay Pumping From a Pressurized SourceRelay Pumping From a Pressurized SourceRelay Pumping From a Pressurized Source Discipline: D/O Name: Officer #: Evaluator: Officer #: Date: Location: The The The The Driver/OperatorDriver/OperatorDriver/OperatorDriver/Operator:::: a) Positions the pumper to operate at a fire hydrant ................................... 2.0 _____ b) Engages the pump ............................................................................... 2.0 _____ c) Operates pumper pressure control systems ........................................... 2.0 _____ d) Operates the volume/pressure transfer valve (multistage pumps only) .... 1.0 _____ e) Correctly operates auxiliary cooling systems .......................................... 1.0 _____ f) Makes the transition between internal and external water sources ........... P/FP/FP/FP/F _____ g) Assembles hose lines, nozzles, valves and appliances ............................ 1.0 _____ h) Provides the correct pressure and flow to the next pumper in the relay ... P/FP/FP/FP/F _____ i) Maintains safe residual pressure ............................................................ 2.0 _____ j) Performs entire operation safely ............................................................. P/FP/FP/FP/F _____ Points Points Points Points PosPosPosPossiblesiblesiblesible Passing Passing Passing Passing ScoreScoreScoreScore AttemptAttemptAttemptAttempt Performance RatingPerformance RatingPerformance RatingPerformance Rating (Points)(Points)(Points)(Points) PASSPASSPASSPASS FAILFAILFAILFAIL 11 8 First Second Third