I. I. I. I. ObjectiveObjectiveObjectiveObjective
Pump a supply line of 2-1/2 inches or larger, given a relay pumping evolution the length
and size of the line and the desired flow and intake pressure, so that the correct pressure and flow
are provided to the next pumper in the relay.
II. II. II. II. Instructions Instructions Instructions Instructions –––– Procedures for Achieving the ObjectiveProcedures for Achieving the ObjectiveProcedures for Achieving the ObjectiveProcedures for Achieving the Objective
Given a fire department pumper as the source pumper, the Driver/Operator shall properly
position and set up the apparatus to pump in relay to a designated relay apparatus.
III. III. III. III. Examiner’s NoteExaminer’s NoteExaminer’s NoteExaminer’s Note
The Driver/Operator will not be allowed to review the performance steps at the time of
testing. The receiving pumper needs 350 GPM. The pumpers must be a minimum of 300 feet
apart.
IV. IV. IV. IV. Preparation & EquipmentPreparation & EquipmentPreparation & EquipmentPreparation & Equipment
A. Two fire department pumpers
B. Minimum of 300 ft. of hose, 2-½ inches in diameter or larger
C. Hydrant
V. V. V. V. Reference SourcesReference SourcesReference SourcesReference Sources
A. IFSTA, Pumping Apparatus Driver/Operator Handbook, 2nd Edition
B. TCFP, Performance Standard, Section 700-5.2
C. NFPA 1002, 5.2.1, 5.2.2, 5.2.4
PB 404.02I – Relay Pumping from a Pressurized Source Page 2 of 2
404.02I – Relay Pumping From a Pressurized SourceRelay Pumping From a Pressurized SourceRelay Pumping From a Pressurized SourceRelay Pumping From a Pressurized Source
Discipline: D/O
Name: Officer #:
Evaluator: Officer #:
Date: Location:
The The The The Driver/OperatorDriver/OperatorDriver/OperatorDriver/Operator::::
a) Positions the pumper to operate at a fire hydrant ................................... 2.0 _____
b) Engages the pump ............................................................................... 2.0 _____
c) Operates pumper pressure control systems ........................................... 2.0 _____
d) Operates the volume/pressure transfer valve (multistage pumps only) .... 1.0 _____
e) Correctly operates auxiliary cooling systems .......................................... 1.0 _____
f) Makes the transition between internal and external water sources ........... P/FP/FP/FP/F _____
g) Assembles hose lines, nozzles, valves and appliances ............................ 1.0 _____
h) Provides the correct pressure and flow to the next pumper in the relay ... P/FP/FP/FP/F _____
i) Maintains safe residual pressure ............................................................ 2.0 _____
j) Performs entire operation safely ............................................................. P/FP/FP/FP/F _____
Points Points Points Points
PosPosPosPossiblesiblesiblesible
Passing Passing Passing Passing
ScoreScoreScoreScore
AttemptAttemptAttemptAttempt
Performance RatingPerformance RatingPerformance RatingPerformance Rating
(Points)(Points)(Points)(Points)
PASSPASSPASSPASS
FAILFAILFAILFAIL
11 8 First
Second
Third