Loading...
HomeMy WebLinkAboutPB 404.02G REVISED 10-2009PPPEEERRRFFFOOORRRMMMAAANNNCCCEEE BBBEEENNNCCCHHHMMMAAARRRKKKSSS 404404404404.0.0.0.02G 2G 2G 2G Changing Water SupplyChanging Water SupplyChanging Water SupplyChanging Water Supply Anne Huff, Fire ChiefAnne Huff, Fire ChiefAnne Huff, Fire ChiefAnne Huff, Fire Chief Beaumont Fire-Rescue Services Discipline:Discipline:Discipline:Discipline: D/OD/OD/OD/O EffEffEffEffective:ective:ective:ective: 6666/5/200/5/200/5/200/5/2002222 Revised:Revised:Revised:Revised: 10/5/200910/5/200910/5/200910/5/2009 Replaces:Replaces:Replaces:Replaces: Driver Benchmark 213 Driver Benchmark 213 Driver Benchmark 213 Driver Benchmark 213 I. I. I. I. ObjectiveObjectiveObjectiveObjective The Driver/Operator, given a fire department pumper, shall change the water supply from the apparatus water tank to an external source while operating a fire attack line of 1-½ or larger so that the flow is not interrupted and the pressure is maintained. II. II. II. II. Instructions Instructions Instructions Instructions –––– Procedures for Achieving the ObjectiveProcedures for Achieving the ObjectiveProcedures for Achieving the ObjectiveProcedures for Achieving the Objective Given a fire department pumper, you shall charge the water supply from the apparatus water tank to an external source while operating a fire attack line of 1-½ or larger so that the flow is not interrupted and the proper pressure is maintained. The skill will end when you state to me that you have completed all the identified steps. Do you understand these instructions? III. III. III. III. Examiner’s NoExaminer’s NoExaminer’s NoExaminer’s Notetetete The Driver/Operator will not be allowed to review the performance steps at the time of testing. IV. IV. IV. IV. Preparation & EquipmentPreparation & EquipmentPreparation & EquipmentPreparation & Equipment A. Fire department pumper B. External source of water (hydrant) V. V. V. V. Reference SourcesReference SourcesReference SourcesReference Sources A. IFSTA, Pumping Apparatus Driver/Operator Handbook, 2nd Edition B. TCFP, Performance Standard, Section 705-2.02 C. NFPA, 1002 3-2.1 PB 404.02G – Changing Water Supply Page 2 of 2 404.02G – Changing Water Supply Discipline: D/O Name: Officer #: Evaluator: Officer #: Date: Location: If the If the If the If the Driver/Operator:Driver/Operator:Driver/Operator:Driver/Operator: (No partial points(No partial points(No partial points(No partial points given)given)given)given) a) Engages pump ...................................................................................... 1.0 _____ b) Exits the apparatus safely ....................................................................... 1.0 _____ c) Opens the tank-to-pump valve .............................................................. 1.0 _____ d) Opens handline discharge valve slowly, and locks into place .................. 1.0 _____ e) Increases engine rpm to the proper pressure for the attack line, and verbalizes the discharge ....................................................................... 1.0 _____ f) Sets the pressure control device .............................................................. 1.0 _____ g) Connects the supply line from the hydrant to the pumper intake and ensures water supply to the pumper (bleeds off air from LDH supply line) ..................................................................................................... 1.0 _____ h) Opens the intake valve and closes the tank-to-pump valve ..................... 1.0 _____ i) Verbalizes residual pressure, then throttles rpms to proper setting for pumping handline ................................................................................. 1.0 _____ j) Closes discharge valves slowly ............................................................... 1.0 _____ k) Disengages pump ................................................................................. 1.0 _____ Points Points Points Points PossiblePossiblePossiblePossible Passing Passing Passing Passing ScoreScoreScoreScore AttemptAttemptAttemptAttempt Performance RatinPerformance RatinPerformance RatinPerformance Ratingggg (Points)(Points)(Points)(Points) PASSPASSPASSPASS FAILFAILFAILFAIL 11 8 First Second Third