Loading...
HomeMy WebLinkAboutPB 402.11E REVISED 7-5-2010PPPEEERRRFFFOOORRRMMMAAANNNCCCEEE BBBEEENNNCCCHHHMMMAAARRRKKKSSS 404040402222.1.1.1.11111EEEE Using a PitUsing a PitUsing a PitUsing a Pitot Tube aot Tube aot Tube aot Tube and Gaugend Gaugend Gaugend Gauge Anne Huff,Anne Huff,Anne Huff,Anne Huff, Fire ChiefFire ChiefFire ChiefFire Chief Beaumont Fire-Rescue Services Discipline:Discipline:Discipline:Discipline: Water SuppliesWater SuppliesWater SuppliesWater Supplies Effective:Effective:Effective:Effective: 1/1/20011/1/20011/1/20011/1/2001 Revised:Revised:Revised:Revised: 7/5/20107/5/20107/5/20107/5/2010 Replaces:Replaces:Replaces:Replaces: Firefighter Benchmark #84Firefighter Benchmark #84Firefighter Benchmark #84Firefighter Benchmark #84 I. I. I. I. ObjectiveObjectiveObjectiveObjective The firefighter, given the necessary equipment, shall read and record the flow pressures to determine the discharge in gallons per minute. II. II. II. II. Instructions Instructions Instructions Instructions –––– Procedures for Achieving the ObjectiveProcedures for Achieving the ObjectiveProcedures for Achieving the ObjectiveProcedures for Achieving the Objective Given all of the necessary equipment, you shall record the flow pressures from two different sized orifices. The examiner shall verify the readings. You shall then use the chart provided and locate the pressure for each orifice. The examiner will indicate the pressure and the GPM indicated by you on the bottom of this performance standard form. You will begin on my instruction to start. The skill will end when you state to me that you have completed all of the identified steps. Do you understand these instructions? III. III. III. III. ExaExaExaExaminer’s Noteminer’s Noteminer’s Noteminer’s Note The firefighter trainee will not be allowed to review the performance steps at the time of testing. Orifice size may be changed by utilizing solid bore nozzle. IV. IV. IV. IV. Preparation & EquipmentPreparation & EquipmentPreparation & EquipmentPreparation & Equipment A. Pitot tube and gauge B. Conversion chart C. Hydrant D. Nozzle or 2-½” to 1-½” reducer E. The firefighter trainee shall accomplish the skill wearing gloves, trousers, and boots. V. V. V. V. Reference SourcesReference SourcesReference SourcesReference Sources A. TCFP, Performance Standards, Section 163-8.01 B. NFPA, National Fire Protection Association 1001, 4-5.4 C. IFSTA Essentials of Fire Fighting 4th Edition, page 394. PB 402.11E – Using a Pitot Tube and Gauges Page 2 of 2 402.11E - Using a Pitot Tube and Gauge Discipline: Water Supplies Name: Officer #: Evaluator: Officer #: Date: Location: If the firefighter:If the firefighter:If the firefighter:If the firefighter: (No partial points given(No partial points given(No partial points given(No partial points given Orifice # 1: a) Opens the hydrant fully ......................................................................... 1.0 _____ b) Opens the petcock on the pitot tube to drain all the water from the chamber ............................................................................................... 1.0 _____ c) Closes the petcock ................................................................................. 1.0 _____ d) Places the blade opening of the pitot tube in the corner of the stream and at a distance approximately half the diameter of the orifice .............. 1.0 _____ e) Places the pitot tube parallel to the opening ........................................... 1.0 _____ f) Records the pressure from the gauge ..................................................... 1.0 _____ g) Properly locates the pressure for each orifice on the chart ....................... 1.0 _____ Pressure Indicated by FF _____Pressure Indicated by FF _____Pressure Indicated by FF _____Pressure Indicated by FF _____ GPM IndicateGPM IndicateGPM IndicateGPM Indicated by FF _____d by FF _____d by FF _____d by FF _____ Orifice # 2: a) Opens the hydrant fully ......................................................................... 1.0 _____ b) Opens the petcock on the pitot tube to drain all the water from the chamber ............................................................................................... 1.0 _____ c) Closes the petcock ................................................................................. 1.0 _____ d) Places the blade opening of the pitot tube in the corner of the stream and at a distance approximately half the diameter of the orifice .............. 1.0 _____ e) Places the pitot tube parallel to the opening ........................................... 1.0 _____ f) Records the pressure from the gauge ..................................................... 1.0 _____ g) Properly locates the pressure for each orifice on the chart ....................... 1.0 _____ Pressure IndicaPressure IndicaPressure IndicaPressure Indicated by FF _____ted by FF _____ted by FF _____ted by FF _____ GPM Indicated by FF _____GPM Indicated by FF _____GPM Indicated by FF _____GPM Indicated by FF _____ Points Points Points Points PossiblePossiblePossiblePossible Passing Passing Passing Passing ScoreScoreScoreScore AttemptAttemptAttemptAttempt PerPerPerPerformance Ratingformance Ratingformance Ratingformance Rating (Points)(Points)(Points)(Points) PASSPASSPASSPASS FAILFAILFAILFAIL 14 10 First Second Third