HomeMy WebLinkAboutPB 402.09F REVISED 12-2012 RENUMBEREDPPPEEERRRFFFOOORRRMMMAAANNNCCCEEE BBBEEENNNCCCHHHMMMAAARRRKKKSSS
402402402402....09090909FFFF
Hand Laying 2Hand Laying 2Hand Laying 2Hand Laying 2----½ inch Supply Line½ inch Supply Line½ inch Supply Line½ inch Supply Line
Anne Huff,Anne Huff,Anne Huff,Anne Huff, Fire ChiefFire ChiefFire ChiefFire Chief
Beaumont Fire-Rescue Services
Discipline:Discipline:Discipline:Discipline: HoseHoseHoseHose
Effective:Effective:Effective:Effective: 1/1/20011/1/20011/1/20011/1/2001
Revised:Revised:Revised:Revised: 12121212////5/5/5/5/2020202012 12 12 12 RENUMBEREDRENUMBEREDRENUMBEREDRENUMBERED
Replaces:Replaces:Replaces:Replaces: FFFFFFFF Benchmark #65Benchmark #65Benchmark #65Benchmark #65; PB 402.09H; PB 402.09H; PB 402.09H; PB 402.09H
I. I. I. I. ObjectiveObjectiveObjectiveObjective
The firefighter, operating as team member, shall demonstrate the proper method of hand
laying at least 200 feet of 2-½ inch supply line or larger from a pumper to a water source.
II. II. II. II. Instructions Instructions Instructions Instructions –––– Procedures for AchiProcedures for AchiProcedures for AchiProcedures for Achieving the Objectiveeving the Objectiveeving the Objectiveeving the Objective
Given the proper equipment you and two (2) or more team members shall demonstrate
the proper method of hand laying at least 200 feet of 2-½ inch or larger supply line from a
pumper to a water source. You will each be graded on your individual actions, but this is a team
exercise and the final evaluation for each of you is determined by the overall team score. You
will begin on my instruction to start. The skill will end when the final performing team member
states to me that all of the identified steps have been completed. Do you understand these
instructions?
III. III. III. III. Examiner’s NoteExaminer’s NoteExaminer’s NoteExaminer’s Note
The firefighter will not be allowed to review the performance steps at the time of testing.
IV. IV. IV. IV. Preparation & EquipmentPreparation & EquipmentPreparation & EquipmentPreparation & Equipment
A. Pumper
B. Sufficient amount of 2-½ inch supply hose
C. Water supply (hydrant or second pumper)
D. Necessary adapters and tools
E. The firefighter shall accomplish the skill wearing helmet, gloves, trousers, and boots.
V. V. V. V. Reference SourcesReference SourcesReference SourcesReference Sources
A. TCFP, Performance Standards, Section 106-6.00, 8.00.
B. NFPA, 1001 3-3.14(b).
C. IFSTA, Essentials of Fire Fighting, 4th Edition, pages 475-476.
PBPBPBPB 404040402222....09090909FFFF –––– Hand Laying 2Hand Laying 2Hand Laying 2Hand Laying 2----½ inch Supply Line½ inch Supply Line½ inch Supply Line½ inch Supply Line Page Page Page Page 2222 of of of of 2222
402.09F - Hand Laying 2-½ inch Supply Line
Discipline: Hose
Name:
Officer #:
Evaluator:
Officer #:
Date:
Location:
If the firefighter:If the firefighter:If the firefighter:If the firefighter: (No partial (No partial (No partial (No partial points given)points given)points given)points given)
FF1FF1FF1FF1 FF2FF2FF2FF2 FF3FF3FF3FF3
a) Firefighter 1 positions on the rear step of the
apparatus………………………………………..1.0
b) Firefighter 2 positions at the tailboard facing
the direction of travel……………………………1.0
c) Firefighter 1 brings the hose from behind back
over the shoulder so that the nozzle can be held
chest high…………………………………….….1.0
d) Firefighter 2 brings the hose from behind back
over the shoulder so that the rear fold ends at the
back of the knee…………...……………….......1.0
e) Firefighter 1 makes a fold in front that ends at
knee height and brings the hose back over the
shoulder..………………………………………..1.0
f) Firefighter 2 continues to make knee-high folds
until the appropriate amount of hose is
loaded…………………………………………...1.0
g) Firefighter 2 holds the hose to prevent it from
slipping off the shoulder…………..…………...1.0
h) Firefighter 2 moves forward approximately
fifteen (15) feet (5 meter)……………………....1.0
i) Firefighter 3 positions at the tailboard facing
the direction of travel…………………………...1.0
j) Firefighter 3 loads hose onto the shoulder in the
same manner as FF2, making knee-high folds
until the appropriate amount of hose is
loaded…………………………………………...1.0
k) Firefighter 2 and 3 advance the hose toward the
water source while flaking hose off the shoulder
(1point each)…………………………………….1.0
l) Firefighter 2 uses adapters and tools to connect
hose to the water supply………………..……...1.0
TOTAL………………………………………………… TOTAL………………………………………………… TOTAL………………………………………………… TOTAL…………………………………………………
Points Points Points Points
PossiblePossiblePossiblePossible
Passing Passing Passing Passing
ScoreScoreScoreScore
AttemptAttemptAttemptAttempt
Performance RatingPerformance RatingPerformance RatingPerformance Rating
(Points)(Points)(Points)(Points)
PASSPASSPASSPASS
FAILFAILFAILFAIL
12 9 First