Loading...
HomeMy WebLinkAboutRES 13-090RESOLUTION NO.13 -090 BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF BEAUMONT: THAT the City Manager be and he is hereby authorized to grant a Utility Crossing Agreement to TransCanada Keystone Pipeline, LP, substantially in the form attached hereto as Exhibit "A," to install a thirty -six inch (36 ") pipeline which will cross various water line and sanitary sewer easements near Hebert Road, West Port Arthur Road, FM 3514 and Highway 347 located outside the city limits of Beaumont for the purpose of transporting oil, said pipeline is to be constructed in compliance with City requirements. 2013. PASSED BY THE CITY COUNCIL of the City of Beaumont this the 30th day of April, APPLICATION FOR UTILITY CROSSING AGREEMENT OUTSIDE THE CORPORATE LIMITS OF THE CITY OF BEAUMONT THE STATE OF TEXAS § COUNTY OF JEFFERSON § Business Name: 1rans P,r uAad0s. KQ45h"P- & iN U7Business Phone:( ) I S - 03-VIP0 Business Address: i � TGxas �i4e 2400 l MMA,51 n l X 1100 � The City of Beaumont, hereinafter called "City ", for and in consideration of the sum specified herein Sle+ F D hereby grants to 'Trayv, (AMAAk,, 4�" Q t�e� he. , L P hereinafter called "Licensee ", the license to lay, maintain, operate, replace, or remove a pipeline for the transportation of oil, gas, water, or products, on or across the following City easement and/or property situated outside the City of Beaumont, Jefferson County, Texas, but being within our Extra - Territorial Jurisdiction (ETJ) and /or Certificate of Convenience and Necessity (CCN) and being more particularly described in Exhibit "A" attached hereto and made a part hereof for all purposes. Nearest Street Distance to Easement length (Linear Foot) of Crossing Vc&r -i0tk s - See V0,rtPk&-% EXHIBIT "A" COST OF LICENSE: Licensee shall make payment to the City of Beaumont as follows: o License Agreement fee - $500.00 Annual fee of $2.25 per linear foot of pipeline located within City property. Said fee shall be reset on January 31, 2011 and shall be reset every ten (10) years, thereafter, to a level to be determined by the City Council or their delegated representative. All fees, including the first annual fee for linear foot usage shall be made to the Water Utilities Department and payable to the City of Beaumont prior to construction. This license is granted by the City of Beaumont subject to conditions. Failure to comply with the following may result in termination of agreement (see page 8). GENERAL CONDITIONS: a Licensee does not intend to sell product for resale from the covered pipeline to customers located within the City; however, Licensee recognizes that should it sell product for resale from this covered pipeline to customers within the City, it will be required to report such distribution and when lawfully required to do so, pay a street rental fee based on revenues. The annual fee and the regulations controlling the payment of such fee will be those as lawfully established by the ordinances of the City. o All pipelines crossing City of Beaumont utility easements, water or sanitary sewer easements shall be bored from easement line to easement line. Within these limits, the pipeline shall be protected by casing or other method approved by the City Water Utilities Department. o The pipeline shall be constructed in such a manner as approved by the City so as it does not interfere with the use of the City property., o The pipeline shall be installed a minimum of three (3) feet below ground and a minimum of five (5) feet below the lowest existing or proposed ditch grades, waterlines, sanitary sewer lines or storm drainage lines, unless otherwise authorized by the City. Such grades and lines shall be indicated on map submittal, as well as depth of proposed pipeline (see page 3). 2 The construction and operation of the pipeline shall not interfere with the natural drainage in that area nor with the drainage system of the City, nor with sanitary sewer lines, waterlines, or other utilities. Damage to existing ditch grade during construction or maintenance of the pipeline shall be corrected and the ditch grade shall be restored to the condition and grade at which it existed prior to construction or maintenance. Bore pits shall be backf`illed according to City standards. Excavations necessary for the construction; repair, or maintenance of the pipeline shall be performed in such a manner that will cause minimal inconvenience to the public. Licensee shall promptly restore the area to as good a condition as before working thereon and to the reasonable satisfaction of the City's Water Utilities Department. o Operations along easements shall be performed in such a manner that all property where operations are performed will be 'restored to original condition or better. No equipment or installation procedures will be used which will damage any structures. The cost of any repairs to structures, sanitary'sewer lines, water lines or other easement features as a result of this installation will be bore by the owner of this line. o Any construction which takes place in, on, under, above, or across property not owned by the City shall require additional permission by the owners) of the property involved. Written proof of said permission is to be provided to the City as part of the application process. Approval of this Iicense agreement excludes permission to do any construction on property which is not owned by the City of Beaumont. l o Any licenses, permits or agreements required by another governmental entity (County, State or Federal) to adjoining property shall be obtained and a copy of such document shall be provided to the City. o Licensee shall be responsible for acquiring all agreements necessary for the lawful use of any private property. o A map showing the location of the proposed pipeline shall be provided. o The pipeline shall be maintained and operated in such a manner as not to leak and/or cause damage to the City property. Once the pipeline is in operation, any damage that occurs to the pipeline which results in exposure or release of product must be reported immediately to the City Fire Department and Water Utilities Department. Licensee shall fully cooperate with the Fire Department and provide, or assist with providnig, any and all necessary notifications, evacuations or other necessary actions. Leaks or other defects are to be repaired immediately by Licensee at it's own cost. o The Licensee shall be responsible for the cleanup and remediation of contaminated areas due to exposure or release of product and any and all costs associated with said cleanup and remediation. o The Licensee shall be responsible for any and all costs associated with the relocation of the pipeline. As provided, the necessity for relocation of the pipeline shall be solely within the discretion of City. o Installation will be done in accordapoe with all City standards and statutes of the State of Texas. REOUIRED COVERAGE: o Licensee shall furnish the City with a Certificate of Standard Liability insurance, including bodily injuries and property damage, naming the City of Beaumont as an Additional Insured. Such policy shall provide for the following minimum coverage: o Bodily injuries: $ 300,000.00 per person $1,000,000.00 per incident o Property Damage: $1,000,000.00 Such insurance shall be maintained in force and effect during the construction or required maintenance of the pipeline and during the life of the pipeline. Such certificate shall contain a provision that at least fifteen (15) days written notice must be given to the City prior to cancellation, alteration, or modification of such insurance. a Licensee shall have in fore with the City a surety bond in the principal amount of $1,000,000.00. The bond shall be payable to the City of Beaumont for the use and benefit of any person entitled thereto and conditioned that the principal and surety will pay all damages to any person caused by, or arising from, or growing out of any violation of the terms of this agreement. The bond shall provide that it may not be cancelled, altered, or otherwise modified without giving fifteen (15) days prior written notice to the City. The bond shall be good and in effect for a period of one (1) year from the date of completion of construction of the pipeline. o Licensee shall indemnify, save and hold harmless the City of Beaumont 4 from any and all claims for injuries and damages to persons or property occasioned by or arising out of the construction, maintenance, operation, repair or removal of the pipeline. This indemnity expressly extends to claims alleging negligence by the City of Beaumont, it's agents, officers or employees, arising from actions taken or occurrences under this license agreement. If the pipeline or any part thereof installed by Licensee shall be in any respect damaged or injured by City or any of its agents or employees in connection with the performance of any work or repairs that may be done upon the property mentioned herein: Licensee shall not be entitled to prosecute or maintain a claim against the City of Beaumont 'for any such damage or injuries so sustained by it; however, said conditions shall -not prevent Licensee from recovering against any contractor who shall damage Licensee's property in the course of such contractor's performance of any contract with the City. OTHER CONSTRUCTION AINTENANC WITHIN PR I'ERTY: City will use its best efforts to notify Licensee of any proposed construction and/or maintenance, to be done by City forces or by contract for the. City, within the property involved with this license. Notification, to Licensee, of other construction and /or maintenance permitted by the City and within the property involved with this license will be the responsibility of the company obtaining said permit. Licensee shall mark the location of its lines within forty -eight (48) hours after receipt of such notification of proposed construction. Licensee shall maintain a local, or toll free, telephone number to be called for notification of construction or maintenance and for location of lines. Such number, or charges to such number, will be provided to the City (Water Utilities Department) and kept current at all times. This number shall be provided to entities permitted to construct, maintain or excavate within this City property and which are required to provide notification of such work. When information has been relayed to Licensee,. through the phone number provided, such contact shall constitute notification for Licensee to provide location of its lines. Failure, by Licensee, to respond within the required time frame shall alleviate the responsibility of the person(s) requiring the lines to be relocated. a City reserves the right to lay, and to pen-nit to be laid, sewer, gas, water and other pipes and cables, and to do or permit to be done any underground 5 work that may be deemed to be necessary or proper by City in, across, along, or under the property. In doing or permitting any such work, the City of Beaumont shall not be liable to Licensee for any damage occasioned; it being understood that nothing herein shall be construed as foreclosing Licensee's rights to recover damages against any contractor or third party who may be responsible for damages to Licensee's facilities. o Whenever by reason of the change in the grade of the property occupied by Licensees' pipeline, or by reason of the location or manner of constructing drainage structures, water pipes, gas pipes, sewers, or other underground construction for any purpose whatever, it shall be deemed necessary by City to relocate, alter, encase, change, adopt or conform the pipeline of Licensee thereto, such change shall be made promptly by Licensee at its cost and without claim for reimbursement or damages against City. If the change is demanded by the City for the benefit of any other person or private corporation, except the City, Licensee shall be reimbursed fully by the person or corporation desiring or occasioning such change for any expense arising out of such change; Licensee will, upon notice from. the City, make such change immediately and at its own cost; it being understood that City will not participate in any part of the cost of any change involving relocation, altering, encasing, boring, or changing in' any manner of the pipeline where same is within City property. NOTIFICA'ITONJINRECTION: Any and all work to. be performed on City property shall be observed and inspected by a City representative. Any work to be performed within the City limits will be subject to periodic inspection to ensure compliance with construction standards. o Licensee shall provide the City (Water Utilities Department) forty -eight (48) hours prior to the installation of the lines permitted by this license. A representative will be scheduled to be present. The expense of such inspection services may be billed to the Licensee and such amounts will be reimbursed to the City. Licensee shall notify the Water Utilities Department at least forty -eight (48) hours prior to completion of work and removal of equipment from the job site to pennit the City to make an inspection. Cal SPECIAL CONDITIONS: Nonasdgnable This license is personal to the Licensee. It is nonassignable and any attempt to assign this license will terminate the license privileges granted to Licensee hereunder. Termination This agreement is subject to termination by the City if any condition specified herein is not met. This agreement may also be terminated by the Licensee. Either party attempting to terminate this agreement shall give written notice to the other specifying the date of, and the reason for, termination. Such notice shall be given not less than thirty (30) days prior to the termination date therein specified. Any written notice may be effected either by personal delivery or by registered or certified mail, postage prepaid with return receipt requested. Mail notices shall be addressed to the addresses of the parties as follows: City of Beaumont Name of Licensee: - rc�v►s Ci�v+a Ke V� ► ` ►�� ► L P.O. Box 3827 '�� T2xGS •- �Su►�G ��b� Beaumont, Texas 77704 Address of Licensee: Attn: City Manager City and State of Licensee: !'�eu�, T� '�1�113ti. Upon cancellation, the pipeline shall be removed and property restored to a condition acceptable to the Water Utilities Director. In the event of cancellation, any and all monies collected for fees associated with this agreement will remain the property of the City. There will be no reimbursements. VA Commencement of work on the pipeline by Licensee after the date of this fully executed license shall be construed as evidence of Licensee's acceptance and approval of the conditions above set forth. IN WH`NESS. WHEREOF, the City of Beaumont, Texas, has caused these presents to be signed by its City Manager and the seal of the City to be herewith affixed by the City Clerk, this day of , A.D. 20 ATTEST: City Clerk CITY OF BEAUMONT, TEXAS Kyle Hayes, City Manager APPLICANT'S COMPANY NAME: (Licensee) lr �C,�06 �?�,%f -) L? e►1 Ike dPcc&0. iOV45 IK� . yRepreseflted by: RNs IOU Title ATTEST: By. Secrets Ricardo S. Lopez Authorized Signatory Ti f�- 8 '111-i m Ming sli 191 loi 1 219, k'091 i a E m P 0 c eCl Lo, A • Vol w i R 0. O 0 x z z �Y o rc UP ♦ Pig 0 .. . ... . ..... a E m P 0 c eCl Lo, A • Vol w i R 0. O 0 x z z �Y o rc UP ♦ Pig 0 JEFFERSON COUNTY TEXAS DAVID A. CUNNINGHAM SURVEY, ABSTRACT N0. 1511 x N A t FLOW 21ft. / j EAOSiNGC 130942.876 NORTHING: 10886068.36 PROPOSED sI `'O' EASnNc: 1301668.69 36 PIPELINE j f /3��� l% l l l TI �,�It T l \Q�J y�aJ`� y� +\Q� � 0 � o 7• Q Q Q Q� Qe Q¢ 0 Lr 0 'i� 4 a e � � °tea° a� °�� �` 4� 4 F LO rn + C'4 pxpx O O ♦ ry ryx�O,Qryxry� ^�'y 'h a + + P P h<• �P. 1P. �P. �P. �P. �, y� `ryP,`p;�p• qP•,`Y. .`P• yy. v .n V, in r y yip. PRODUCT: CRUDE OIL CARRIER PIPE (ROAD HDD): 36" 0.0. X 0.748' W.T. PLAN COORDINATES BASED ON X-•70M DSAW PIPE W/14 TO 16 MILS FBE & 30 MILS ARO HORIZ: 1" =100' UTM ZONE 15 NORTH, MINIMUM TEST PRESSURE: 1,816 PSIG NAD83, U.S. SURVEY FEET MAXIMUM OPERATING PRESSURE: 1,440 PSIG' CARRIER PIPE TO BE EXTERNALLY COATED La FOR CORROSION CONTROL NOTE: PIPELINE TO BE CATHODICALLY PROTECTED ACTUAL SEWER/WATER LINE LOCATION PIPEUNE DESIGN AS PER REQUIREMENTS OF PART 195 I= rQ TO BE VERIFIED PRIOR TO CROSSING OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) z TRAFFIC TO BE MAINTAINED DURING INSTALLATION a PIPELINE TO BE INSTALLED BY HORIZONTALLY DIRECTIONAL ORiLLED a 4 N n 1 o iva rva 47N- 40' _ ...... ...... ................. ... ...... 40' NATURAL. GROUND .................. .......... ......... .._ . 30' . ...... ......... ........... ............................... 20' 10' ................ :................. .............16- PVC WATER UTILITY .. . 12" PVC -FM 1o' SANITARY SEWER 0' ... ... .................... 0, ............. .. ..... ............................ .. ..... —10' �8 .... .. ............................... ...... .... _ —20' ....... .. ........... 20' —30' . ...... .......................... ....... 30' 5' MIN. CLEARANCE ----5' MIN. CLEARANCE s—40' ......... .. ........ ... .. .. ......... I ......... I.... ........... —40' —50, P F —60' TO O PROPOSED ...... ... ..................... .... I 70' * . .. .. ....... —70' ! 4 - 36 PIPELINE . I # —80' ................... 80 ............. ............................... . h —90' I ...— ....... ....... ... _ _ .. ... ....... ... —100 ! PROF„ILE I I HORIZ: 1" =100' j VERT: 1 " =50' I z 16" PVC WATER UTILITY & 12" PVC --FM SANITARY SEWER CROSSING DRAWING PERMIT 2° ! TransCanada FIA CHANAGE: DISCIPLINE f F � I In?>'•' % "f ,,� dv!tr;;' 4387 M.P. 478.60 03 ClniversaiPegasus I ! t n+, BRNA71ONAI, ORIGINATOR: TITLE KEYSTONE XL - GULF COAST I I 4848 LOOP CENTRAL OR. PI 01/07/2013 SUITE 100 HOUSTON, Tx, PROPOSED PIPELINE CROSSING i F 71 77081 -7776 AP ED BY: 1S" PVC WATER UTILITY & 12" PVC-FM SANITARY SEWER 1 JOB NO. 11042.00 IG—L GTC SCALE 1" =100' DWG No 4387- 03 —ML -03 -504 IREV 1 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS 1 1 1 I I D 1 1 I I I I EFFERSON COUNTY TEXAS DAVID A. CUNNINGHAM SURVEY. ABSTRACT NO. 15 N 3' 77 T PROAPOSED 1 FLOW _ /56* PIPELINE NORTHING: 10885924,79 EASTENG: 1305474.62 � J 2 fl? a . ll w W z y h fn N fi� in 12 j w W W 4 lU J NT N N PLAN COORDINATES BASED ON HORIZ: 1 " =40' NOTE UTM ZONE 15 NORTH, ACTUAL SEWER /WATER LINE LOCATION NAD83, U,S. SURVEY FEET TO BE VERIFIED PRIOR TO CROSSING PRODUCT: CRUDE OIL CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618" W.T. X -70M OSAW PIPE W/14 TO 16 MILS FBE & 30 MILS ARO MINIMUM TEST PRESSURE: 1,816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHODICALLY PROTECTED PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING w r d p Off 3 O + + 7 p � a E 30' .......ROUN ... ....................... .. ................ ................. 30' NATURAL GROUND ................ ... ....... 20' 16" PVC WATER UTILITY•- -- ......... 10' 0' TOP OF PROPOSED--/ . ..... 0' 5' MIN. CLEARANCE --10' 36" PIPELINE ............. ... I I PROFILE HORIZ: 1 " =40' VE R T: I"=40' z I ° 1/N 16" PVC WATER UTILITY CROSSING DRAWING PERMIT TransCanada FIA # CHAINAGE: DISCIPLINE I III , r:a„ t.:,,:,.; +.•�: UIliveisalI egasus 4387 M.P. 479.27 D3 I I ' "'{" "^" TITLE °""'. ORIGINATOR: KEYSTONE XL — GULF COAST I I SUIT L00 cEwraAl TR. UPI 1/07/2013 PROPOSED PIPELINE CROSSING SUITE I� "ousrorl, TX. 7707' P" 16" PVC WATER UTILITY 71s- 977 -7770 CHECK APPROVED BY: JOB NO. 11042.00 Iii —L GTC SCALE 1 „_40' DWG No 4387- =03 —ML- 03-505 REV 0 PLOTTED SIZE: ANSI A (8.501) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS JEFFERSON COUNTY, TEXAS WILLIAM CARROLL SURVEY, ABSTRACT NO. 13 Q,Q PROPOSED b NORTHING: 10887426.79 `" PIPELINE x \ \ FASTING: 1306530.48 r - r� r\ 4 ♦ \ �y0 rx r Sr 46 y ' , \4 s Oir rpxr� sr srq sr S ,! r4 c,S Ox , O 69 r xs9 q \ rX O r 9�4 go ♦O� Q11 \.� O.n \ Orr egyk ,pp \ \ ,Pp•�O ELALL COORDINATES BASED ON HORIZ: 1 " =3O' UTM ZONE 15 NORTH, NAD83, U.S. SURVEY FEET PRODUCT: CRUDE OIL NOTE: ACTUAL SEWER/WATER LINE LOCATION CARRIER PIPE (ROAD BORES): 36' O.D. X 0.618" W.T. TO BE VERIFIED PRIOR TO CROSSING X -70M DSAW PIPE W/14 TO 16 MILS FBE & 30 MILS ARID MINIMUM TEST PRESSURE: 1,816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHODICALLY PROTECTED PIPELINE DESIGN AS PER REOUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING r r J I-- 5 w r - 0 X O 3 0. .............................................. ............................... 30' NATURAL 16" PVC WATER UTILITY 20' ............ ....... .......... GROUND ..... .......... 20' v—'- .. I .............................. .. ........ 10' 0' . ............................... TOP OF PROPOSED ...... 0' 5' MIN. CLEARANCE 36" PIPELINE .............................. _ .... ............................... .......................................... ......... —10' 1 PROFILE 1 HORIZ: 1 " =30' I VERT: 1 " =30' 1 I I I � z I In 16" PVC WATER UTILITY CROSSING DRAWING I W PERMIT TransCanada ° TransCanada FIA CHAINAGE: DISCIPLINE N UniversalPegasus ,:, ;:.,, ,, a =:kr,r 4387 479.63 03 1 IEIRNAI IJ.aAL ORIGINATOR: TITLE KEYSTONE XL — GULF COAST I I I I 4848 LOOP CENTRAL OR. UPI 01 07 2013 SUITE 100 HOUSTON. TX PROPOSED PIPELINE CROSSING 711 PH. 7137077;770 CHECKED BY: APPROVED Sr. FARM TO MARKET ROAD 3514 JOB NO. 11042.00 IG -L GTC SCALE 1 " =30' Dwc "O 4367- 03 -ML -03 -506 R� 0 PLOTTED SIZE: ANSI A (8.501) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS IA a 0 A JEFFERSON COUNTY TEXAS DAVID A. CUNNINGHAM SURVEY, ABSTRACT NO. 15 a/ ti Q / a� a PR�OSED 60' a 60• NORTHING: 10887768.87 / 36" PIPELINE EASTING: 1306771.22 / FLOW a QS 3 ?` .`O OQ p P Ty y a/ NORTHIN G: 10887778.37 EASTING: 1306777.90 7 COORDINATES BASED ON �V UTM ZONE 15 NORTH, NAD83, U.S. SURVEY FEET J h� O% h lim NOTE: ACTUAL SEWER /WATER LINE LOCATION TO BE VERIFIED PRIOR TO CROSSING NATURAL GROUND 16" PVC WATER UTILITY -\ - " - - - 1 20' Im L- D, ...... , 5' MIN: CLEARANCE 5' MIN. CLEARANCE 0, TOP OF PROPOSED -10' 36" PIPELINE .. .. -1D' PROFILE HORI Z: I"=20' VERT: 1 " =20' S" PVC SANITARY SEWER & 16" PVC WATER UTILITY CROSSING DRAWING PERMIT TransCanada FIA CHAINAGE: DISCIPLINE iJniversalPega us ^,,,, 4387 M.P. 479.7 03 1141 ERNATtON AL ORIGINATOR: TITLE KEYSTONE XL -- GULF COAST SLAT LDS HOUSTON. TR. PROPOSED PIPELINE CROSSING swrE ,00 Nousrow. Tx. UPI 01 07 2013 a'sii PiiTO HECKED BY: APPROVED BY: $" PVC SANITARY SEWER & 16" PVC WATER UTILI7Y JOB NO. 11042.00 IG —L GTC I SCALE 1 " =20' 1 DWG No 4387- 03 —ML -03 -507 I REV 0 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS t 1 1 I I I I t I I 1 z I w° F I I I I I PLAN HORIZ: 1 " =20' PRODUCT: CRUDE OIL CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618" W.T. X -70M OSAW PIPE W /14 TO 16 MILS FBE do 30 MILS ARO MINIMUM TEST PRESSURE: 1,816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHODICALLY PROTECTED PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING C r g ' Vi a O O 0 F{O-- En W VI Oo .............. 20 I- 6" PVC SANITARY SEWER- � lim NOTE: ACTUAL SEWER /WATER LINE LOCATION TO BE VERIFIED PRIOR TO CROSSING NATURAL GROUND 16" PVC WATER UTILITY -\ - " - - - 1 20' Im L- D, ...... , 5' MIN: CLEARANCE 5' MIN. CLEARANCE 0, TOP OF PROPOSED -10' 36" PIPELINE .. .. -1D' PROFILE HORI Z: I"=20' VERT: 1 " =20' S" PVC SANITARY SEWER & 16" PVC WATER UTILITY CROSSING DRAWING PERMIT TransCanada FIA CHAINAGE: DISCIPLINE iJniversalPega us ^,,,, 4387 M.P. 479.7 03 1141 ERNATtON AL ORIGINATOR: TITLE KEYSTONE XL -- GULF COAST SLAT LDS HOUSTON. TR. PROPOSED PIPELINE CROSSING swrE ,00 Nousrow. Tx. UPI 01 07 2013 a'sii PiiTO HECKED BY: APPROVED BY: $" PVC SANITARY SEWER & 16" PVC WATER UTILI7Y JOB NO. 11042.00 IG —L GTC I SCALE 1 " =20' 1 DWG No 4387- 03 —ML -03 -507 I REV 0 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS t 1 1 I I I I t I I 1 z I w° F I I I I I I I I I 1 I D i I I t I I JEFFERSON COUNTY, TEXAS WILLIAM P. HUMPHRIES SURVEY, ABSTRACT NO. 32 rl /,- W w Oy �, a b� J �! J I PRODUCT: CRUDE OIL CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618' W.T. X -70M DSAW PIPE W/14 TO 16 MILS FBE & 30 MILS ARO MINIMUM TEST PRESSURE: 1,616 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHOOK:ALLY PROTECTED PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO 8E INSTALLED BY BORING � I 75• FLOW Ib— 3 / I NORTHING: 10888464.10 EASTING: 130726D.47 PERMIT FIA # 4387 CHAINAGE: M.P. 480.05 DISCIPLINE 03 UniversaIPegasus tiO3e O ~ INTERNATIONAL ORIGINATOR: 4848 LOOP CENTRAL DR. PI 01/07/2013 3 SUITE 100 HOUSTON, TX. -97t I ELAN HORIZ: 1 " =20' PROPOSED - 36" PIPELINE COORbINATES BASED ON UTM ZONE 15 NORTH, NAD83, U.S. SURVEY FEET 1.XL ACTUAL SEWER /WATER LINE LOCATION TO BE VERIFIED PRIOR TO CROSSING ` � yc��?5���., .... ........ ....... . .......... . ............. I .......... .........ya .,,moo ............ 8" WATER UTILITY 1 0' LO ~- ................ ..... .............. ........... lo, CLEARANCE .. TOP OF PROPOSED 0' o' ..... .... .. PROFILE ...... .. 36" PIPELINE HORIZ: 1"=20' VERT: 1 " =20' 0 z 8" WATER UTILITY CROSSING DRAWING V) PERMIT FIA # 4387 CHAINAGE: M.P. 480.05 DISCIPLINE 03 UniversaIPegasus TransCanada ,s: „,•,; - „, °'° TITLE KEYSTONE XL — GULF COAST INTERNATIONAL ORIGINATOR: 4848 LOOP CENTRAL DR. PI 01/07/2013 PROPOSED PIPELINE CROSSING SUITE 100 HOUSTON, TX. -97t Bn WATER UTILITY CHECK Y: APPROVED T13_g»_»>D I(;-L GTC JOB NO. 11042.00 scALE 1 ” =20. awG No 4387- 03 —ML -03 -508'' 0 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS I 1 i I I I I I I I tz I I u° F JEFFERSON COUNTY, TEXAS WILLIAM P. HUMPHRIES SURVEY, ABSTRACT NO. 32 POWER POLE — P —P —P —P P— P —P— —P —P— P��,,}}P— P —P —P —P P-- P J P _"" P P 20.7' 20.2' 90. PROPOSED > FLOW � 36" PIPELINE I L\ PRODUCT: CRUDE OIL HORIZ: 1 " =20' Ngm- CARRIER PIPE (ROAD BORES): 36" 0.0. X 0.618" W.T. ACTUAL SEWER /WATER LINE LOCATION X— 70M DSAW PIPE W/14 TO 16 MILS FBE do 30 MILS ARO TO BE VERIFIED PRIOR TO CROSSING MINIMUM TEST PRESSURE: 1.816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHOLICALLY PROTECTED PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING o: r Ir 4 Q O Uf Q ° a NATURAL GROUND 20' ....... .. ....... ....... .............. ..................... .... ...... ...... 20' —15" PVC SANITARY SEWER lo- ------ .-------------- :� ........ ............. ................... ................... .......................... ........ 10' 5' MIN. 0' 0 .... CLEARANCE ..................... .... OF PROPOSED ......... . PROFILE 36" PIPELINE HORIZ: i"=20' VER T: 1"=20' CA z 15" PVC SANITARY SEWER CROSSING DRAWING K s PERMIT NORTHING: 10888831.08'. EASTING: 1307518.72 CHAINAGE: 1 M.P. 480.05 I DISCIPLINE A 03 1Wj1 UniversalYegasus pt� �s COORDINATES BASED ON i 141 ERNAS IONAL w UTM ZONE 15 NORTH, DR. 4848 O aATR L R. t00 PI 01 07 2013 PROPOSED PIPELINE CROSSING g NAD83, U.S. SURVEY FEET ;11 QU N .0 w \� - w o} APPROVED BY: + JOB NO_ 11042.00 IG -L o a Z �4 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS J \ N� L\ PRODUCT: CRUDE OIL HORIZ: 1 " =20' Ngm- CARRIER PIPE (ROAD BORES): 36" 0.0. X 0.618" W.T. ACTUAL SEWER /WATER LINE LOCATION X— 70M DSAW PIPE W/14 TO 16 MILS FBE do 30 MILS ARO TO BE VERIFIED PRIOR TO CROSSING MINIMUM TEST PRESSURE: 1.816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHOLICALLY PROTECTED PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING o: r Ir 4 Q O Uf Q ° a NATURAL GROUND 20' ....... .. ....... ....... .............. ..................... .... ...... ...... 20' —15" PVC SANITARY SEWER lo- ------ .-------------- :� ........ ............. ................... ................... .......................... ........ 10' 5' MIN. 0' 0 .... CLEARANCE ..................... .... OF PROPOSED ......... . PROFILE 36" PIPELINE HORIZ: i"=20' VER T: 1"=20' CA z I I I I I I W m F 15" PVC SANITARY SEWER CROSSING DRAWING K PERMIT FIA # 4387 CHAINAGE: 1 M.P. 480.05 I DISCIPLINE A 03 UniversalYegasus TransCanada III en fnrnrm", 11) aoh,e, TITLE KEYSTONE XL — GULF COAST i 141 ERNAS IONAL ORIGINATOR: DR. 4848 O aATR L R. t00 PI 01 07 2013 PROPOSED PIPELINE CROSSING O:Nraa SLAT -7770 15" PVC SANITARY SEWER 713'977 HECKED BY: APPROVED BY: JOB NO_ 11042.00 IG -L GTC SCALE 1 " =20' DWG No 4387- 03 —ML -03 -509 REV 0 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS I I I I I I W m F 1 1 1 1 D I 1 I I I JEFFERSON COUNTY TEXAS WILLIAM HUMPRIES SURVEY ABSTRACT NO. 32 PIPELINE DESIGN AS PER REOLMREMENTS OF PART 195 w rX ~ w OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) r r y �� Cw 8 O / PROPOSED rn H 3 84'84' y ( 36" PIPEUNE FLOW h 10 NORTHING: 10889524.18 EASTING: 1308420.78 I I HORIZ: 1 "= 40' NORTHING: 1088 952 7.19 EASTING: 1308425.83 COORDINATES BASED ON PRODUCT: CRUDE OIL UTM ZONE 15 NORTH. CARRIER PIPE (ROAD BORES): 36' O.D. X 0.618" W.T. NAD83. U.S. SURVEY FEET X -70M OSAW PIPE W/14 TO 16 MILS FBE do 30 MILS ARO MINIMUM TEST PRESSURE: 1,816 PSIG o MAXIMUM OPERATING PRESSURE: 1,440 PSIG NOTE: CARRIER PIPE TO BE EXTERNALLY COATED W ACTUAL SEWER/WATER LINE LOCATION FOR CORROSION CONTROL TO BE VERIFIED PRIOR TO CROSSING PIPELINE TO BE CATHODICALLY PROTECTED PIPELINE DESIGN AS PER REOLMREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) r r PIPELINE TO BE INSTALLED BY BORING a a a ro 1 10 o O+ + + a a a > r in 30' 20' 10' 0' —10' ..... ......... ...... . 1 .... 18" PVC SANITARY SEWER 16' PVC WATER UTILITY NATURAL GROUND ........,.N. .. ...... ............. .... ...�.... ............. TOP OF PROPOSED s' MIN. CLEARANCE 5' MIN. CLEARANCE 36" PIPELINE PROFILE HORIZ: 1"=40' VER T: 1"=40' 40' 30' 20' 10' 0' —10' V) Lgn 16" PVC WATER UTILJTY & 18" PVC SANITARY SEWER CROSSING DRAWING uj PERMIT TransCanada FIA CHAINAGE: flISCIPLINE If UniversalPegasus 111 e —im SS u: dwiw -, 4387 M.P. 480.18 03 INTERNATIONAI ORIGINATOR: TITLE KEYSTONE XL — GULF COAST `UIT `°°" HOUSTON °a. PROPOSED PIPELINE CROSSING SUITE 100 HOUSTON. Tx. UPI 01/04/2012 713 - 77 70 CHECKED APPROVED BY: 16 ". PVC WATER UTILITY & 18" PVC SANITARY SEWER JOB NO. 11042.00 IG--L I GTC I SCALE 1 " =40' DWG No 4387- 03 —M1 -03 -510 IREv 0 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS 1 i i 1 I I W F 1 i i 1 I I W F JEFFERSON COUNTY. TEXAS WILLIAM P. HUMPHRIES SURVEY, ABSTRACT NO. A -32 / OU PONT ROAD _Ij �Y j I i I 1 POWER POLE II 1 l i m L =f +{JiI NORTHING: 30893471.84 i 1 1 I i"�' >4 EASTING. 1313519.98 • ` 8a PROPOSED I - m I I 36" PIPELINE '^ FLOW I4 Q U Q 4 ~ •� I I C) < POWER POLE — Ig i I o W � = o �° ui %I 1w I 6 m� tD�(7 rc� l9 l� III: a f'Y� 1- U. ! W +ICI'- W Uu C�IUY �lllll W l�'1 W Oial C3 N t ! p p1 Y N O .P O N1 O N 01 Ull% W 0 N t[f tO a` m01 O rn N + s �. + + +u + + 1, + + + + t , 010 .-) O �� III 0 p �O �O Ot 0IN 0 _ O 0+04 OVERHEAD POWERLINE PLAN. COORDINATES BASED ON HORIZ: 1 " =60' UTM ZONE 15 NORTH, NAD83, U.S. SURVEY FEET PRODUCT: CRUDE OIL CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618" W.T. X -70M OSAW PIPE W /14 TO 16 MILS FBE & 30 MILS ARO MINIMUM TEST PRESSURE: 1,816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED NOTE, FOR CORROSION CONTROL ACTUAL SEWER/WATER LINE LOCATION PIPELINE TO BE CATHODICALLY PROTECTED TO BE VERIFIED PRIOR TO CROSSING PIPELINE DESIGN AS PER REOUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING a 3 p m u1 O KA o + ± a F N .......................... ................. . ........ .. . . . ... . ...................... ............. 30' ...................................................................................................................................................... ............................... NATURAL GROUND _.. . _ ........ ............... .........................._.... 20` ............ . ........................ •' "' 8" PVC-05 WATER UTILITY —+'• .................................................................. ............................... 10' t . ........ ._..... ....... ._.._..... TOP OF PROPOSED 5 MIN. CLEARANCE 1 36 N PIPELNE ............ . ..... .. . ....................... o' .......................... ............................. .. 0' � I 1 HORIZ: 1 " =60' I I VERT: 1"=20' N Z ca 0 8" PVC'05 WATER UTILITY CROSSING DRANNG PERMIT F° 1 TransCat7ada Fv, B CHAINAGE: DISCIPLINE # I I UniversalPegmus �i n lxrsincas 10 denv : 4387 M.P. 481.52 03 1 1 TITLE KEYSTONE XL — GULF COAST 4N1(ERNATIONAL I t ORIGINATOR: 4846 LOOP CENTRAL DR. p1 1 07 2013 PROPOSED PiPEUNE CROSSING SUITE 100 NWSTON, T%. 77081 PH. U.S. HIGHWAY 347 t t CH CK D BY: APP VED BY: 713 - 977 -7770 IG —L GTC JOB NO. 11042.00 SCALE 1 " =60' DWG No 4387- 03 —ML -03 -511 REV 0 PLOTTED SIZE: ANSI A (8.501) 1) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS APPLICATION FOR UTILITY CROSSING AGREEMENT OUTSIDE THE CORPORATE LIMITS OF THE CITY OF BEAUMONT THE STATE OF TEXAS § COUNTY OF JEFFERSON Business Name:TrWAIV PAIML. Keowe Pig iM libusiness Phone: 03-V/00 Business Address: %17 TC oLS S tide a400 ok510�4 � The City of Beaumont, hereinafter called "City", for and in consideration of the sum specified herein 5114. $ D grants to Trrkv►S Lwta.� km"c Q ig0 i v%2 , L P hereinafter called "Licensee ", the license to lay, maintain, operate, replace, or remove a pipeline for the transportation of oil, gas, water, or products, on or across the following City easement and/or property situated outside the City of Beaumont, Jefferson County, Texas, but being within our Extra - Territorial Jurisdiction (ETJ) and/or Certificate of Convenience and Necessity (CCN) and being more particularly described in Exhibit "A" attached hereto and made a part hereof for all purposes. Nearest Street Distance to Easement Length (Linear Footl of Crossing Vrkri OWS -Set oAko, 4•ed eA105 21$ .3 Varlc,u,s S4ra4s 4y iviGk!_ _ Pov4 w-y .. FYI A51 i COST OF LICENSE: Licensee shall make payment to the City of Beaumont as follows: o License Agreement fee - $500.00 Annual fee of $2.25 per linear foot of pipeline located within City property. Said fee shall be reset on January 31, 2011 and shall be reset every ten (10) years, thereafter, to a level to be determined by the City Council or their delegated representative. All fees, including the first annual fee for linear foot usage shall be made to the Water Utilities Department and payable to the City of Beaumont prior to construction. This license is granted by the City of Beaumont subject to conditions. Failure to comply with the following may result in termination of agreement (see page 8). GENERAL CONDITIONS: o Licensee does not intend to sell product for resale from the covered pipeline to customers located within the City; however, Licensee recognizes that should it sell product for resale from this covered pipeline to customers within the City, it will be required to report such distribution and when lawfully required to do so, pay a street rental fee based on revenues. The annual fee and the regulations controlling the payment of such fee will be those as lawfully established by the ordinances of the City. o All pipelines crossing City of Beaumont utility easements, water or sanitary sewer easements shall be bored from easement line to easement line. Within these limits, the pipeline shall be protected by casing or other method approved by the City Water Utilities Department. o The pipeline shall be constructed in such a manner as approved by the City so as it does not interfere with the use of the City property.' The pipeline shall be installed a minimum of three (3) feet below ground and a minimum of five (5) feet below the lowest existing or proposed ditch grades, waterlines, sanitary sewer lines or storm drainage lines, unless otherwise authorized by the City. Such grades and lines shall be indicated on map submittal, as well as depth of proposed pipeline (see page 3). 2 The construction and operation of the pipeline shall not interfere with the natural drainage in that area nor with the drainage system of the City, nor with sanitary sewer lines, waterlines, or other utilities. Damage to existing ditch grade during construction or maintenance of the pipeline shall be corrected and the ditch grade shall be restored to the condition and grade at which it existed prior to construction or maintenance. Bore pits shall be backfilled according to City standards. Excavations necessary for the construction, repair, or maintenance of the pipeline shall be performed in such a manner that will cause minimal inconvenience to the public. Licensee shall promptly restore the area to as good a condition as before working thereon and to the reasonable satisfaction of the City's Water Utilities Department. o Operations along easements shall be performed in such a manner that all property where operations are performed will be restored to original condition or better. No equipment or installation procedures will be used which will damage any structures. The cost of any repairs to structures, sanitary'sewer lines, water lines or other easement features as a result of this installation will be borne by the owner of this line. o Any construction which takes place in, on, under, above, or across property not owned by the City shall require additional permission by the owner(s) of the property involved. Written proof of said permission is to be provided to the City as part of the application process. Approval of this license agreement excludes permission to do any construction on property 1 which is not owned by the City of Beaumont. o Any licenses, permits or agreements required by another governmental entity (County, State or Federal) to adjoining property shall be obtained and a copy of such document shall be provided to the City. o Licensee shall be responsible for acquiring all agreements necessary for the lawful use of any private property. o A map showing the location of the proposed pipeline shall be provided. The pipeline shall be maintained and operated in such a manner as not to leak and/or cause damage to the City property. Once the pipeline is in operation, any damage that occurs to the pipeline which results in exposure or release of product must be reported immediately to the City Fire Department and Water Utilities Department. Licensee shall fully 3 cooperate with the Fire Department and provide, or assist with providing, any and all necessary notifications, evacuations or other necessary actions. Leaks or other defects are to be repaired immediately by Licensee at it's own cost. The Licensee shall be responsible for the cleanup and remediation of contaminated areas due to exposure or release of product and any and all costs associated with said cleanup and remediation. o The Licensee shall be responsible for any and all costs associated with the relocation of the pipeline. As provided, the necessity for relocation of the pipeline shall be solely within the discretion of City. o Installation will be done in accordance with all City standards and statutes of the State of Texas. REQUIRED COVERAGE: o Licensee shall furnish the City with a Certificate of Standard Liability Insurance, including bodily injuries and property damage, naming the City of Beaumont as an Additional Insured. Such policy shall provide for the following minimum coverage: o Bodily injuries: $ 300,000.00 per person $1,000,000.00 per incident o Property Damage: $1,000,000.00 Such insurance shall be maintained in force and effect during the construction or required maintenance of the pipeline and during the life of the pipeline. Such certificate shall contain a provision that at least fifteen (15) days written notice must be given to the City prior to cancellation, alteration, or modification of such insurance. Licensee shall have in force with the City a surety bond in the principal amount of $1,000,000.00. The bond shall be payable to the City of Beaumont for the use and benefit of any person entitled thereto and conditioned that the principal and surety will pay all damages to any person caused by, or arising from, or growing out of any violation of the terms of this agreement. The bond shall provide that it may not be cancelled, altered, or otherwise modified without giving fifteen (15) days prior written notice to the City. The bond shall be good and in effect for a period of one (1) year from the date of completion of construction of the pipeline. Licensee shall indemnify, save and hold harmless the City of Beaumont 4 from any and all claims for injuries and damages to persons or property occasioned by or arising out of the construction, maintenance, operation, repair or removal of the pipeline. This indemnity expressly extends to claims alleging negligence by the City of Beaumont, it's agents, officers or employees, arising from actions taken or occurrences under this license agreement. If the pipeline or any part thereof installed by Licensee shall be in any respect damaged or injured by City or any of its agents or employees in connection with the performance of any work or repairs that may be done upon the property mentioned herein: Licensee shall not be entitled to prosecute or maintain a claim against the City of Beaumont for any such damage or injuries so sustained by it; however, said conditions shall -not prevent Licensee from recovering against any contractor who shall damage Licensee's property in the course of such contractor's performance of any contract with the City. OTHER CONSTRUCTION/MAINTENANCE WITHIN PROPERTY: City will use its best efforts to notify Licensee of any proposed construction and/or maintenance, to be done by City forces or by contract for the. City, within the property involved with this license. Notification, to Licensee, of other construction and/or maintenance permitted by the City and within the property involved with this license will be the responsibility of the company obtaining said permit. Licensee shall mark the location of its lines within forty-eight (48) hours after receipt of such notification of proposed construction. Licensee shall maintain a local, or toll free, telephone number to be called for notification of construction or maintenance and for location of lines. Such number, or charges to such number, will be provided to the City (Water Utilities Department) and kept current at all times. This number shall be provided to entities permitted to construct, maintain or excavate within this City property and which are required to provide notification of such work. When information has been relayed to Licensee,. through the phone number provided, such contact shall constitute notification for Licensee to provide location of its lines. Failure, by Licensee, to respond within the required time frame shall alleviate the responsibility of the person(s) requiring the lines to be relocated. City reserves the right to lay, and to permit to be laid, sewer, gas, water and other pipes and cables, and to do or permit to be done any underground 5 work that may be deemed to be necessary or proper by City in, across, along, or under the property. In doing or permitting any such work, the City of Beaumont shall not be liable to Licensee for any damage occasioned; it being understood that nothing herein shall be construed as foreclosing Licensee's rights to recover damages against any contractor or third party who may be responsible for damages to Licensee's facilities. o Whenever by reason of the change in the grade of the property occupied by Licensees' pipeline, or by reason of the location or manner of constructing drainage structures, water pipes, gas pipes, sewers, or other underground construction for any purpose whatever, it shall be deemed necessary by City to relocate, alter, encase, change, adopt or conform the pipeline of Licensee thereto, such change shall be made promptly by Licensee at its cost and without claim for reimbursement or damages against City. If the change is demanded by the City for the benefit of any other person or private corporation, except the City, Licensee shall be reimbursed fully by the person or corporation desiring or occasioning such change for any expense arising out of such change; Licensee will, upon notice from the City, make such change immediately and at its own cost; it being understood that City will not participate in any part of the cost of any change involving relocation, altering, encasing, boring, or changing in any manner of the pipeline where same is within City property. NOTIFICATIONANSPECTION: o Any and all work to be performed on City property shall be observed and inspected by a City representative. Any work to be performed within the City limits will be subject to periodic inspection to ensure compliance with construction standards. o Licensee shall provide the City (Water Utilities Department) forty -eight (48) hours prior to the installation of the lines permitted by this license. A representative will be scheduled to be present. The expense of such inspection services may be billed to the Licensee and such amounts will be reimbursed to the City. Licensee shall notify the Water Utilities Department at least forty-eight (48) hours prior to completion of work and removal of equipment from the job site to permit the City to make an inspection. 6 SPECIAL CONDITIONS: Nonassignable This license is personal to the Licensee. It is nonassignable and any attempt to assign this license will terminate the license privileges granted to Licensee hereunder. Termination This agreement is subject to termination by the City if any condition specified herein is not met. This agreement may also be terminated by the Licensee. Either party attempting to terminate this agreement shall give written notice to the other specifying the date of, and the reason for, termination. Such notice shall be given not less than thirty (30) days prior to the termination date therein specified. Any written notice may be effected either by personal delivery or by registered or certified mail, postage prepaid with return receipt requested. Mail notices shall be addressed to the addresses of the parties as follows: City of Beaumont Name of Licensee: TraKS C0.V41A" Y WSFan Pi ,c OVIYke i L? P.O. Box 3827 Beaumont, Texas 77704 Address of Licensee: '� �� T�xr�4 SMI ��b� Attn: City Manager City and State of Licensee: OOWS�o4, , TX 1900). Upon cancellation, the pipeline shall be removed and property restored to a condition acceptable to the Water Utilities Director. In the event of cancellation, any and all monies collected for fees associated with this agreement will remain the property of the City. There will be no reimbursements. 7 Commencement of work on the pipeline by Licensee after the date of this fully executed license shall be construed as evidence of Licensee's acceptance and approval of the conditions above set forth. IN WITNESS. WHEREOF, the City of Beaumont, Texas, has caused these presents to be signed by its City Manager and the seal of the City to be herewith affixed by the City Clerk, this fS i day of 4 A.D. 20j3-. A Clerk ATTEST- By: �1 OF s� CITY OF BEAUrr MONT, TEXAS By: C_ 1 Kyle Hayes, City Manager APPLICANT'S COMPANY NAME: (Licensee) ir(ny►S C.a r. KeuSv�G \ ;,�Ci by a ev►} TG O• Pi tettue 8per +JM5 Represelfted by: A, 47AM Title / Ricardo S. Lopez Authortwd so atm T;4Ic Dmu wrroamoon%r rojecmiironst, anaoa_ neyawne_ k. Uf_ c, oaenMape\ L, ayDrneaUmonIX 4J=-N- ML- uc- /Ua_tM8U onLLMZ.MXa HILLEBRANDT RD Z � w D D D D D D? Z D Z D D Z D D D D m N IM -0 m oo v Onr)r) r) nnTn O Z 3 A A A A A A A A V V V V V V V V P 1 + �l�pOp l0 la lG tp0� IO Po. O P. pQo� 0101 W 10 00 01 N N W V • X O O y� yi a m G W O O o 19 1W0 T m - o co �; b o V o O iD ran n n O Nmm p N H rG H N ` yyA�U {{A��,� yyA,,�� {{A�,,�r yyA�,� yAy,,�� wwA Z m O n 2 w 0 3 n to 7 m d r r r- r r r r r r r r Z m � 3 y m y Nooc�b���V bSc7iis N � HEBERT RD 0 0 0 D � 0 p v = � Z r n 0 3 v t N EYt v v i yyd y�oa� 9r-7=. i 0 A �pT N 2 0 c ° 7 a < g m 0 2 m 2 inn p 8 1 CO) m ° m ° � m m m m 0 1 N Alk In o _r m m z Z O 0 A c al O m m a N y m z N ig 9r-7=. i SUNSHINE DR J 3 w H A 06 A �pT N 2 0 c 7 0 2 m 2 inn p 0 G) z � b m m m 0 0 0 N Alk d o SUNSHINE DR J 3 w H A 06 r 2 0 c 7 t7r o p n W p 0 G) N N N N 3 d o SUNSHINE DR J 3 w H A 06 JEFFERSON COUNTY, TEXAS DAVID A. CUNNINGHAM SURVEY. ABSTRACT NO. 15 i h0* 5N � � / NORTHING: 10886069.56 / \ FLOW _ EASTING: 1301942.87 A.Z."A \ " % �� NORTHING: 1088606 \ PROPOS 1 50' EASTING: 1301968.89 .89 ED 36 PIPELINE '? �? �? �� 2 2�? ? �? �2 U a c) o, �i." 4� �� �� 4 %- 4,�Iu4'(i.J�i� 4.�'<i.� 4" 4" t: O ~ QQ �Q QQ QQ Q�Q PL�+Q�QQ� Q�Q QQ QQ 0 o o Ox 0 0Ox 0 y Ox a ti Ox 1 � `x O ^ ,x e °j �x ryx ryx ��o Q x r1x^jx o� yoe at oQ cr c°f w g - ��4r Lo Lo 08) rL Vp Q 'f y00 'klvI 0 1* yx O,x rn N N 0� yam? 4'- 4y 4y 4y 0qP 0�P `P xh, ^� �PO� OIP yl ylF y�P 4y a d 5ti 1 0 x V N Ln PRODUCT: CRUDE OIL PLAN. CARRIER PIPE (ROAD HDD): 36" O.D. X 0.748" W.T. PLAN COORDINATES BASED ON X -70M DSAW PIPE W/14 TO 16 MILS FBE k 30 MILS ARO HORIZ: 1" =100' UTM ZONE 15 NORTH, MINIMUM TEST PRESSURE: 1,816 PSIG NAD83, U.S. SURVEY FEET MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED w FOR CORROSION CONTROL V) PIPELINE TO BE CATHODICALLY PROTECTED ACTUAL SEWER/WATER LINE LOCATION PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 J a TO BE VERIFIED PRIOR TO CROSSING OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) Z TRAFFIC TO BE MAINTAINED DURING INSTALLATION y PIPELINE TO BE INSTALLED BY HORIZONTALLY DIRECTIONAL DRILLED 00 33 ^ + N> ry> O a a la 10 V N 40 _ ... ... ................ ..... ... ... .. ..................... 40' 30' NATURAL GROUND 30' 20' ...................... ............... .............................. ............................ 20' 10' 16" PVC WATER UTILITY .. 12" PVC-FM SANITARY SEWER 0' ............... ............ o' —10, . ................ ............................. ......... I .............. .... ........ I.................. .................. —10' —20' ............. —20' . ' —30' ...... .............................. as 5 MIN. CLEARANCE —30' 5' MIN. CLEARANCE —40' —40' —50' ..... .... .... .... ..................... .......... ... —50' —60' _ . ............... ........ . . TOP OF PROPOSED -70' 36" PIPELINE ............................... ...................... ............................... _60' 3 -80' ... -so' I -901 ...................... ............................... ......... —90' _ I 1 n —100' 100' I PROFILE. I HORIZ: 1" =100' m 1 z VERT: 1 " =50' I z T 16" PVC WATER UTIUTY & 12" PVC —FM SANITARY SEWER CROSSING DRAWING w el I PERMIT W° TransCanada Fw �! CHAINAGE: DISCIPLINE N UniversalPegasus business r� de,,ver 4387 M.P. 478.60 03 1 INTERNATIONAL ORIGINATOR: TITLE KEYSTONE XL — GULF COAST 1 1 SUIT `� CENTRAL °R. PROPOSED PIPELINE CROSSING sell¢ 1ao DR. PI 01/07/2013, BE 71;'9,7 P 77p CHECKft: AP . 16" PVC WATER UTILITY & 12" PVC —FM SANITARY SEWER JOB NO. 11042.00 IG —L GTC SCALE 1 "= 100' DWG No 4387- 03 —ML -03 -504 IR EV 1 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS JEFFERSON COUNTY, TEXAS DAVID A. CUNNINGHAM SURVEY, ABSTRACT NO. 15 N 3p. f / PROPOSED 3 77 FLOW 36 PIPELINE N OR TH I N G: 108859 2 4.79 2 2 2 2 EASTING: 1305474.62 W W W 4 Q a IQ v1 i vWJ V1 z, V1 2 H J J W � O O / N PLAN COORDINATES BASED ON HORIZ: 1 " =40' UTM ZONE 15 NORTH, NOTE: NAD83, U.S. SURVEY FEET ACTUAL SEWER /WATER LINE LOCATION TO BE VERIFIED PRIOR TO CROSSING PRODUCT: CRUDE OIL CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618" W.T. X -70M DSAW PIPE W/14 TO 16 MILS FBE do 30 MILS ARO MINIMUM TEST PRESSURE: 1,816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHODICALLY PROTECTED PIPELINE DESIGN AS PER REOUIREMENTS OF PART 195 y OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) t TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING w 0o n 3 O + > 0. � a V) rn 30' NATURAL GROUND 30' 20' ...... ....... ......... ................. 20' 16" PVC WATER UTILITY 10' ..................... .......................... 10' 0' TOP OF PROPOSED . ............................... o' 5' MIN. CLEARANCE -10' 36" PIPELINE I 1 I I PROFILE 1 HORIZ: 1 " =40' I z VERT: 1 " =40' Z 16" PVC WATER UTILITY CROSSING DRAWNG 1 W gaok Q TransCanada FIA # CHAINAGE: PERMIT DISCIPLINE # F I 1 UniversalPegasus \ n business rn deliver 4387 M.P. 479.27 03 INTERNATIONAL TITLE 48" LOOP CENTRAL 0R. ORIGINATOR: KEYSTONE XL —GULF COAST SUITE 100 HOUSTON, Tx. PI 1/07/2013 PROPOSED PIPELINE CROSSING I I 713799777 P 770 1HECKED BY: APPROVED 16" PVC WATER UTILITY 1 I JOB NO. 11042.00 IG —L GTC SCALE t " =40' DWG NO 4387- 03 —ML -03 -505 R� 0 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS 1n z 0 JEFFERSON COUNTY, TEXAS WILLIAM CARROLL SURVEY, ABSTRACT NO. 13 PROPOSED NORTHING: 10 " ,. x36 PIPLINE EAST P\gF� FLOW Sp s9\ O \ ♦ \ � \r r 46' 90 x mss\ o \lox"\,� sf s�q sr� ♦ O (e' ST9 q x t^O 5�9 ♦ �l O O sr9 "x" O0 xb XO x J 9 E9 x 6 j FO OT /TC'y O \' �9\ T� � O.n � \ cF 90 0 T 4n ,polo COORDINATES BASED ON PLAN UTM ZONE 15 NORTH, HORIZ: 1' =30' NAD83, U.S. SURVEY FEET PRODUCT: CRUDE OIL CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618" W.T. X -70M DSAW PIPE W /14 TO 16 MILS FBE & 30 MILS ARO MINIMUM TEST PRESSURE: 1,816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHODICALLY PROTECTED PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING J F- W _ O+ O t o a o 3 a U d cil 1O 30' r- ......... ............. ............................... 16" PVC WATER UTILITY Im NOTE: ACTUAL SEWER/WATER LINE LOCATION TO BE VERIFIED PRIOR TO CROSSING ......... .......... ........... I......... .................A ....... 30' NATURAL GROUND — ......... .......... 20' 01 _. LTOP OF PROPOSED ... 5' MIN. CLEARANCE 36" PIPELINE ............................................................................................. ............................... PROFILE HORIZ: 1"=30' VER T: 1"=30' UmVersalPegasus INTERNATIONAL 4848 LOOP CENTRAL DR. SUITE 100 HOUSTON, TX. 77081 PH. 713- 977 -7770 JOB NO. 11042.00 IO 0 one 16" PVC WATER UTILITY CROSSING DRAWING o PERMIT TransCanada FIA N CHAINAGE: DISCIPLINE / in business to defiver 4387 479.63 03 IG -L TITLE KEYSTONE XL — GULF COAST 01/07/2013 PROPOSED PIPELINE CROSSING PPROVED BY: FARM TO MARKET ROAD 3514 GTC SCALE 1., =30 DWG No 4387- 03 —ML -03 -506 REV 0 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS I I I I I I I I I I J I L� I Z I C� I V) I W W 0 � I � I I I I I I I I I I I I I I I i w V) z 0 N JEFFERSON COUNTY, TEXAS DAVID A. CUNNINGHAM SURVEY, ABSTRACT NO. 15 &) / SO . Q P PROPOSED NORTHING: 10887768.87 60' Q 60' 36" PIPELINE FASTING: 1306771.22 / ` / FLOW q- /S ti t J t� P fQ 8�0° zhy xh /Op/ m NORTHING: 10887778.37 EASTING: 1 306 777.90 A q, COORDINATES BASED ON �R UTM ZONE 15 NORTH, NAD83, U.S. SURVEY FEET J hh O% NOTE: ACTUAL SEWER/WATER LINE LOCATION TO BE VERIFIED PRIOR TO CROSSING NATURAL GROUND 16" PVC WATER UTILITY \ —1 20' m 5' MIN. CLEARANCE J ` 5' MIN. CLEARANCE 0� 0. TOP OF PROPOSED -10' 36" PIPELINE -1o, HORIZ: 1"=20' VERT: 1"=20' 8" PVC SANITARY SEWER do 18" 0 0 TransCanada UniversalPegasus io business to deliver INTERNATIONAL ORIGINATOR: 4848 LOOP CENTRAL DR. PI D1 07 20 SUITE 100 HOUSTON, TX, 77081 PH. JOB NO. 11042.00 I IG —L PLOTTED SIZE: ANSI A (8.5x1 1) GTC PVC WATER UTILITY CROSSING DRAWING PERMIT FIA # CHAINAGE: DISCIPLINE Iq 4387 M.P. 479.7 03 TITLE KEYSTONE XL — GULF COAST 13 PROPOSED PIPELINE CROSSING 8" PVC SANITARY SEWER & 16" PVC WATER UTILITY SCALE 1,._20. DWG No 4387- 03 —ML -03 -507 I REV 0 CADD DRAWING: DO NOT MAKE MANUAL REVISIONS I I I I I I I i I I I L3 I 1 W _ F I I I I I I PLAN HORIZ: 1 " =20' PRODUCT: CRUDE OIL CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618" W.T. X— 70M DSAW PIPE W /14 TO 16 MILS FBE do 30 MILS ARO MINIMUM TEST PRESSURE: 1,816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHODICALLY PROTECTED PIPELINE DESIGN AS PER REOUIREMENTS OF PART 195 Of UJI OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION to PIPELINE TO BE INSTALLED BY BORING a Uj Uj °o N a 3 + O + O i a° + O 1O v~i Lt ao In 20' r 8" PVC SANITARY SEWER m NORTHING: 10887778.37 EASTING: 1 306 777.90 A q, COORDINATES BASED ON �R UTM ZONE 15 NORTH, NAD83, U.S. SURVEY FEET J hh O% NOTE: ACTUAL SEWER/WATER LINE LOCATION TO BE VERIFIED PRIOR TO CROSSING NATURAL GROUND 16" PVC WATER UTILITY \ —1 20' m 5' MIN. CLEARANCE J ` 5' MIN. CLEARANCE 0� 0. TOP OF PROPOSED -10' 36" PIPELINE -1o, HORIZ: 1"=20' VERT: 1"=20' 8" PVC SANITARY SEWER do 18" 0 0 TransCanada UniversalPegasus io business to deliver INTERNATIONAL ORIGINATOR: 4848 LOOP CENTRAL DR. PI D1 07 20 SUITE 100 HOUSTON, TX, 77081 PH. JOB NO. 11042.00 I IG —L PLOTTED SIZE: ANSI A (8.5x1 1) GTC PVC WATER UTILITY CROSSING DRAWING PERMIT FIA # CHAINAGE: DISCIPLINE Iq 4387 M.P. 479.7 03 TITLE KEYSTONE XL — GULF COAST 13 PROPOSED PIPELINE CROSSING 8" PVC SANITARY SEWER & 16" PVC WATER UTILITY SCALE 1,._20. DWG No 4387- 03 —ML -03 -507 I REV 0 CADD DRAWING: DO NOT MAKE MANUAL REVISIONS I I I I I I I i I I I L3 I 1 W _ F I I I I I I I 1 I I I I 0 I I I I 1 1 w z 0 0 ai JEFFERSON COUNTY, TUAS WILLIAM P. HUMPHRIES SURVEY, ABSTRACT NO. 32 rl W * Q O I � fq J PRODUCT: CRUDE OIL CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618" W.T. X -70M DSAW PIPE W/14 TO 16 MILS FBE do 30 MILS ARO MINIMUM TEST PRESSURE: 1,816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHODICALLY PROTECTED PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING 20' zo• � / 75• 3 `2� PROPOSED — FLOW 36" PIPELINE 3 / NORTHING: 10888464.10 EASTING: 1307260.47 3 3� O/ J O�qy Q 3/m y gg J d 1�L1 HORIZ: 1"=20' COORDINATES BASED ON UTM ZONE 15 NORTH, NAD83, U.S. SURVEY FEET NOTE, ACTUAL SEWER/WATER LINE LOCATION TO BE VERIFIED PRIOR TO CROSSING 20' ._, ................... — ........... ............................ ............................... . . ............ 8" WATER UTILITY 10' 10� I I 5' MIN. I o' _ . CLEARANCE . TOP OF PROPOSED o' PROFILE 36" PIPELINE HORIZ: 1"=20' I 1 VERT: 1"=20' 1 z 8" WATER UTILITY CROSSING DRAWING I c� W TransCanada E R M IT FIA 4387 CHAINAGEP M.P. 480.05 DISCIPLINE 03 UniversalPegasus in business to deliver F fN7ERNAT�ONAL I 1 ORIGINATOR: TITLE KEYSTONE XL — GULF COAST 4848 LOOP CENTRAL DR. SUITE 100 Ho1sr011, Tx. UPI 01/07/20131 PROPOSED PIPELINE CROSSING H K IG —L 1 JAPPROVED BY: GTC 77081 PH. 713- 977 -7770 p $ WATER UTILITY I I JOB NO. 11042.00 SCALE 1 •• =20' DWG No 4387- 03 —ML -03 -508 REV 0 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS I 1 I I 1 i I I I 1 1 w z 0 0 cy —P —P —P JEFFERSON COUNTY, TEXAS WILLIAM P. HUMPHRIES SURVEY, ABSTRACT NO. 32 701" POWER POLE P P— P— P— P— PP —P —P P P— P —P —P —P P T � P P_P_ 201.7' 20.2' 90 PROPOSED FLOW 1 36" PIPELINE 5' MIN. D' CLEARANCE ........... TOP OF PROPOSED ................ D, PROFILE 36" PIPELINE HORIZ: 1"=20' VERT: 1"=20' 15" PVC SANITARY SEWER CROSSING DRAWING PERMIT TransCanada FIA # CHAINAGE: DISCIPLINE UniversalPegdsus in business to deliver 4387 M.P. 480.05 03 INTERNAT:40NAL ORIGINATOR: TITLE KEYSTONE XL — GULF COAST 4848 `ooP `ANTRAL OR. SUIT PROPOSED PIPELINE CROSSING SUITE 100 NousroN, rx. PI 01/07/2013 713'97; 7770 HtUKtU UY: APPROVED . 15" PVC SANITARY SEWER JOB NO. 11042.00 1 IG -L GTC SCALE 1 „ =20 DWG No 4387- 03 —ML -03 -509 REV 0 PLOTTED SIZE: ANSI A (8.5x1 1) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS 1 i 1 z I I w I F I 1 I I I I I I s NORTHING: 10888831.08 ( 9 EASTING: 1307518.72 ox F > (e� COORDINATES BASED ON w a z S UTM ZONE 15 NORTH, 2 NAD83, U.S. SURVEY FEET 2 In F o > J o a a IQ_ N Q J n 50' \ ELAN PRODUCT: CRUDE OIL HORIZ: 1 " =20' NOTE: CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618" W.T. ACTUAL SEWER /WATER LINE LOCATION .X -70M DSAW PIPE W /14 TO 16 MILS FBE do 30 MILS ARID TO BE VERIFIED PRIOR TO CROSSING MINIMUM TEST PRESSURE: 1,816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHODICALLY PROTECTED PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING o: W Q t- z Q O In O o a d. NATURAL GROUND 20' ............... ..... ..... ... .. ........... .............. 20' 15" PVC SANITARY SEWER 10' ....................................... ............................... ............... .... 10' 5' MIN. D' CLEARANCE ........... TOP OF PROPOSED ................ D, PROFILE 36" PIPELINE HORIZ: 1"=20' VERT: 1"=20' 15" PVC SANITARY SEWER CROSSING DRAWING PERMIT TransCanada FIA # CHAINAGE: DISCIPLINE UniversalPegdsus in business to deliver 4387 M.P. 480.05 03 INTERNAT:40NAL ORIGINATOR: TITLE KEYSTONE XL — GULF COAST 4848 `ooP `ANTRAL OR. SUIT PROPOSED PIPELINE CROSSING SUITE 100 NousroN, rx. PI 01/07/2013 713'97; 7770 HtUKtU UY: APPROVED . 15" PVC SANITARY SEWER JOB NO. 11042.00 1 IG -L GTC SCALE 1 „ =20 DWG No 4387- 03 —ML -03 -509 REV 0 PLOTTED SIZE: ANSI A (8.5x1 1) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS 1 i 1 z I I w I F I 1 I I I I I I I 1 I I I 1 0 i I I I I I JEFFERSON COUNTY, TEXAS WILLIAM HUMPRIES SURVEY. ABSTRACT NO. 32 I z UTILITY & 18" PVC SANITARY SEWER CROSSING DRAWNG W� 1-- W TransCanada J W FIA # V ti� _H I DISCIPLINE li 03 F J I3 J INTERNATIONAL +la ORIGINATOR: TITLE KEYSTONE XL — GULF COAST o,�" � N PI b / Oxb V) (�I N N h 3 84' 84 N I PROPOSED FLOW �~P/ APPROVED BY: 36" PIPELINE � 3 I NORTHING: 10889524.18 I NORTHING: 10889527.19 EASTING: 1308420.78 3 EASTING: 1308425.83 / I30 \ CADD DRAWING: DO I / N a A' \ PLD' AN \\ H ORI Z: 1"=40' COORDINATES BASED ON PRODUCT: CRUDE OIL UTM ZONE 15 NORTH, CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618" W.T. NAD83, U.S. SURVEY FEET X- 70M DSAW PIPE W/14 TO 16 MILS FBE & 30 MILS ARO MINIMUM TEST PRESSURE: 1,816 PSIG a MAXIMUM OPERATING PRESSURE: 1,440 PSIG NOTE: CARRIER PIPE TO BE EXTERNALLY COATED N �I ACTUAL SEWER /WATER LINE LOCATION FOR CORROSION CONTROL F TO BE VERIFIED PRIOR TO CROSSING PIPELINE TO BE CATHODICALLY PROTECTED o PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 < OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) t TRAFFIC TO BE MAINTAINED DURING INSTALLATION N 3 PIPELINE TO BE INSTALLED BY BORING > ; a a u0 io rn o o ± Vf VI 40' F-- ..... ........... .. .................. ..............................~ ...... ............................... .............-1 40' 30' _ ............. ....... .............. ....... ... 30' 18" PVC SANITARY SEWER 16" PVC WATER UTILITY NATURAL GROUND 20' ................. 20' 10, ...................................... ............................... ................ ............................... 10, O' 0, 6' MIN. CLEARANCE 5' MIN. -10' TOP OF PROPOSED . .:........ ..... 36" PIPELINE .......... J — 10' HORIZ: 1"=40' VER T: 1"=40' V) I 16" PVC WATER UTILITY & 18" PVC SANITARY SEWER CROSSING DRAWNG TransCanada PERMIT W FIA # 4387 CHAINAGE: M.P. 480.18 I DISCIPLINE li 03 F UniversalPegasus in business ro deliver INTERNATIONAL ORIGINATOR: TITLE KEYSTONE XL — GULF COAST 4848 LOOP CENTRAL OR. SUITE 100 HOUSTON, TX. PI 01/04/2012 PROPOSED PIPELINE CROSSING I CHECKED BY: APPROVED BY: 71 773'977 H. 16" PVC WATER UTILITY & 18" PVC SANITARY SEWER I JOB NO. 11042.00 IG -L GTC SCALE 1 " =40' DWG No 4387- 03 —ML -03 -510 REV 0 PLOTTED SIZE: ANSI A (8.5x1 1) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS I 1 I 1 I I O o I � I I 1 JEFFERSON COUNTY, TEXAS WIWAM P. HUMPHRIES SURVEY. ABSTRACT NO. A -32 / (j DU PONT ROAD a7� I I II l r l I II ^I POWER POLE la" ZI y Z, xl l j o l o a0 !Ix ! I I I m I I co I NORTHING: 10893471.84 �, FASTING• 1313519 98 PROPOSED 36" PIPEUNE ! l I I 18 tl I FLOW xa I n' I nI U Io Q I M Q I U Q M on I POWER POLE —1 I ;_ I of 1w10 a 0 I wx I= IQ owl 0 Z' IJ 0, <1 lwila H I W Uy C�IUyW (�I W Ci�l W Ox I n t t t OI t 00 Ol + t y t O O 1' t N t f t O0+0 O ) O O O 1 O 04 OVERHEAD POWERLINE PLAN HORIZ: 1"=60' PRODUCT: CRUDE OIL CARRIER PIPE (ROAD BORES): 36" O.D. X 0.618" W.T. X -70M DSAW PIPE W /14 TO 16 MILS FBE do 30 MILS ARO MINIMUM TEST PRESSURE: 1,816 PSIG MAXIMUM OPERATING PRESSURE: 1,440 PSIG CARRIER PIPE TO BE EXTERNALLY COATED FOR CORROSION CONTROL PIPELINE TO BE CATHODICALLY PROTECTED PIPELINE DESIGN AS PER REQUIREMENTS OF PART 195 OF THE CODE OF FEDERAL REGULATIONS (LATEST EDITION) TRAFFIC TO BE MAINTAINED DURING INSTALLATION PIPELINE TO BE INSTALLED BY BORING WIII M W 3 li! ( o 1III i N Kalil � 00 O N J H IY W H Q 3 rn N am o t U 1 d a V) rn 00 COORDINATES BASED ON UTM ZONE 15 NORTH, NAD83, U.S. SURVEY FEET NOTE: ACTUAL SEWER /WATER LINE LOCATION TO BE VERIFIED PRIOR TO CROSSING ao PVC'05 WATER UTIUTY CROSSING DRAWING ....... 30' 20' 10' I 1 I 0' W PERMIT TransCanada FIA M CHAINAGE: DISCIPLINE / F UniversalPegasus in business to deriver 4387 M.P. 481.52 03 INTERNATIONAL TITLE ORIGINATOR: KEYSTONE XL — GULF COAST I 4848 LOOP CENTRAL DR. SUITE 100 HOUSTON, Tx. PI 1/07/2013 PROPOSED PIPELINE CROSSING Nuff 713 -97i»7o CHECKED BY: APPROVED BY: U.S. HIGHWAY 347 JOB NO. 11042.00 IG —L GTC SCALE 1 " =60' DWG No 4387- 03 —ML -03 -511 REV 0 PLOTTED SIZE: ANSI A (8.5x11) CADD DRAWING: DO NOT MAKE MANUAL REVISIONS ACOREIr CERTIFICATE OF LIABILITY INSURANCE DATE(MMMDNYYY) CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, 10122012 THIS CERTIFICATE 13 ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: M the certificate holder Is an ADDITIONAL INSURED, the policy(ies) must be endorsed. fl SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Marsh USA, Inc. 4400 Comerica Bank Tower 1717 Main Street Dallas, TX 75201.7357 — CONTACT NAME: PHONE FAX Ertl, ac No EMAIL ADD INSURERS AFFORDING COVERAGE NAIC S W00050 -GL- -2012 INSURER A : Liberty Mutual Insurance Company 43043 INSURED TRANSCANADA KEYSTONE PIPELINE, LP INSURER B : N/A NIA INSURER C: NIA NIA CITY OF BEAUMONT P.O. BOX 3827 BEAUMONT, TX 77704 INSURER D INSURER E: INSURER F : fFA Qccurr@aWl _ r;.vvcrvwues CERTIFICATE NUMBER: HOILM215121R"l oculeuvU surunrn.,� - - - �... THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR I TYPE OF INSURANCE POLICY NUMBER MM/LIDOY EFF MPaP , .tIMrT3 A GENERAL LIABILITY X T82 -691 - 459482 -022 07/0512012 07/23/2014 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY PRDAMAGE TO FIERT915— EMISES S 10000 fFA Qccurr@aWl _ CLAIMS -MADE a OCCUR MED EXP (Any one person). $ 10,000 X GEN'L AGG - PER SPREAD PERSONAL & ADV INJURY $ 1,0001 000 X 10 -YEAR COMPLETED OPS GENERAL AGGREGATE $ 1,000,000 [ENT AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP /OP AGG $ 1,000,000 POLICY PRO- LOC $ AU7pM0BILE LIABILITY MB I LIMIT (Ea a ident) ANY AUTO BODILY INJURY (Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY (Per accident) $ I P NON-OWNED HIRED AUTOS PRO RTY DAMAGE $ . era t I I $ UMBRELLA LU113 OCCUR EACH OCCURRENCE $ EXCESS UAB CLAIMS -MADE AGGREGATE $ DIED I I RETENTION $ WORKERS COMPENSATION $ WC STATU- OTH- AND EMPLOYERS' LIABILITY YIN ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? N! A E.L. EACH ACCIDENT $ (Mandatory in NH) M describe under E.L. DISEASE - EA EMPLOYE S DESCRIPTION OF OPERATIONS below E.L. DISEASE - POLICY LIMIT $ nccno,s�.nu ne .,a W Vn,,v / ♦—CLES (AUnGh ACC lul, Aaomonar KOMOrKa &OWU1e, H more spats is required) IT IS HEREBY AGREED THAT THE CITY OF BEAUMONT IS ADDED AS AN ADDITIONAL INSURED BUT ONLY WITH RESPECT TO LIABILITY ARISING OUT OF THE OPERATIONS OF THE NAMED INSURED. CITY OF BEAUMONT P.O. BOX 3827 BEAUMONT, TX 77704 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. I William Hines ®1988 -2010 ACORD CORPORATION, AN rights reserved. ACORD 25 (2010105) The ACORD name and logo are registered marks of ACORD Right -of -Way Permit Bond Bond Number: BDTO- 400140 -12 KNOW ALL MEN BY THESE PRESENTS: That we, TransCanada Keystone Pipeline, LP, of 2700 S. Post Oak Blvd., Suite 400 Houston, Texas 77056, as Principal, and Liberty Mutual Insurance Company, as Surety, are held and firmly bound unto The City of Beaumont, Texas, as Obligee, in the sum of One Million - - - - -00 /100 Dollars ($1,000,000.00) Dollars, lawful money of the United States of America, for which payment, we bind ourselves, our heirs, executors, administrators, successors and assigns, jointly and severally. WHEREAS, the Principal has applied to the City of Beaumont for a Pipeline License Agreement to lay, maintain, operate, replace, or remove pipeline for the transportation of oil, gas, water or their products on or across certain property situated in the City of Beaumont, Jefferson County, Texas being more particularly described in the permit application from the City of Beaumont (the "Application for Pipeline License Agreement "); WHEREAS, the Principal is required to file a suitable bond with the Obligee to guarantee satisfactory performance of the conditions of the Permit Agreement before the permission will be granted. Now, therefore, the condition of this bond is such that if the Principal faithfully performs the conditions of the Permit Agreement, then this obligation shall be null and void; otherwise to remain in full force and effect; provided, however, that if the Principal shall fail to faithfully perform the conditions of the Permit Agreement, then the Surety shall have a reasonable period of time upon receiving notice of the Principal's default from the Obligee to either: The Surety may not cancel, alter or otherwise modify this bond unless fifteen (15) days prior written notice is provided to the City. (1) Remedy the default; or (2) Pay to the Obligee the amount necessary to remedy the default, up to the penal sum of this bond. It understood and agreed that the aggregate liability of the Surety shall not exceed the penal sum of this bond. It is a condition of this bond that any suit or action must be commenced before the expiration of one (1) year from the date of the completion date of the work under the Permit Agreement. The Principal and the Surety have signed and sealed this bond this 17 day of October, 2012. TransCanada Keystone Pipelines LP by its �t- General Partner, TransCanada Keystone Pipeline Liberty Mutual Insurance Company (Surety) 6 k. by: Lois Innes Attorney -In -Fact CD E T i n :d' 0 a THIS POWER OF ATTORNEY IS NOT VALID UNLESS IT IS PRINTED ON RED BACKGROUND. This Power of Attorney imits the acts of those named herein, and the have no a manner a y y authority to bind the company except in the manner a the extent herein stated. LIBERTY MUTUAL INSURANCE COMPANY BOSTON, MASSACHUSETTS POWER OF ATTORNEY KNOW ALL PERSONS BY THESE PRESENTS: That Liberty Mutual Insurance Company (the "Company'l, a Massachusetts stock insurance company, pursuant to and by authority of the By -law and Authorization hereinafter set forth, does hereby name, constitute and appoint ... LOIS INNES AND LEAH CARTER...., ALL OF THE CITY OF ...CALGARY .............. PROVINCE OF ... ALBERTA........................................................................................ .............................., each individually If there be more than one named, its true and lawful attomey -in -fact to make, execute, seal, acknowledge and deliver, for and on its behalf as surety and as its act and deed, any and all undertakings, bonds, recognizances and other surety obligations, and the execution of such undertakings, bonds, recognizances and other surety obligations, in pursuance of these presents, shall be as binding upon and Company as if they had been duly signed by the president and attested by the secretary of the company in their own proper persons. That this power is made and executed pursuant to and by authority of the following By -law and Authorization: ARTICLE Xlil — Execution of Contracts: Section 5. Surety Bonds and Undertakings. Any officer of the Company authorized for that purpose in writing by the chairman or the president, and subject to such limitations as the chairman or the president may prescribe, shall appoint such attomeys -in -fact, as may be necessary to act in behalf of the Company to make, execute, seal, acknowledge and deliver as surety any and all undertakings, bonds, recognizances and other surety obligations. Such attomeys -in -fact, subject to the limitations set forth in their respective powers of attorney, shall have full power to bind the Company by their signature and execution of any such instruments and to attach thereto the seal of the Company. When so executed such Instruments shall be as binding as if signed by the president and attested by the secretary. By the following instrument the chairman or the president has authorized the officer or other official named therein to appoint attomeys -in -fact: Pursuant to Article XIII, Section 5 of the By -laws, Paul McIntyre, Assistant Secretary of Liberty Mutual Insurance Company, is hereby authorized to appoint such attorneys -in -fact as may be necessary to act in behalf of the Company to make, execute, seal, acknowledge and deliver as surety any and all undertakings, bonds, recognizances and other surety obligations. That the By -law and the Authorization set forth above are true copies thereof and are now in full force and effect. IN WITNESS WHEREOF, this Power of Attorney has been subscribed by an authorized officer or official of the company and the corporate seal of Liberty Mutual Insurance Company has been affixed thereto in Toronto, Ontario this 17TH day of JANUARY, 2011 . PROVINCE OF ONTARIO CITY OF TORONTO On this 17TH day of JANUARY , 2011, before me, a Notary Public, personally a Assistant Secretary of Liberty Mutual Insurance Company; that he knows the sea Attorney and affixed the corporate seal of Liberty Mutual Insurance Company the .A IN TESTIMONY WHEREOF, I have hereto subscribed my name and affixed ` written. CERTIFICATE LIBERTY MUTUAL INSURANCE COMPANY v „�, BY Paul c , ssistant Secretary McIntyre, to me known, and acknowledged that he is On; and that he executed the above Power of �tt��X.� a r�Ftrfai seal at Tot o, or O: NOTARY PUBLIC rtCtint ry Public first above I, the undersigned, Assistant Secretary of Liberty Mutual Insurance Company in Canada, do he onginal power of attorney of which the foregoing is a full, true and correct copy, is in full force and effect on the date of this certificate; and I do further certify t cer or official who executed the said power of attorney is a Assistant Secretary specially authorized by the chairman or the president to appoint attomeys -in -fact as provided in Article XIII, Section 5 of By -laws of Liberty Mutual Insurance Company. This certificate and the above power of attorney may be signed by facsimile or mechanically reproduced signatures under and by authority of the following vote of the board of directors of Liberty Mutual Insurance Company at a meeting duly called and held on the 12`" day of March, 1980. VOTED that the facsimile or mechanically reproduced signature of any assistant secretary of the company, wherever appearing upon a certified copy of any power of attorney issued by the company in connection with surety bonds, shall be valid and binding upon the company with the same force and effect as though manually affixed. IN TESTIMONY WHEREOF, I have hereunto subscribed my name and affixed the corporate seal of the said company, this �� day �%L -ki ,v'" 71✓' I t� Michael Weiss, Assistant ec