HomeMy WebLinkAboutORD 83-14 ' ORDINANCE 0O. ENTITLED AN ORDINANCE AMENDING CHAPTER 6 , SECTION 6-21 OF THE CODE OF THE ORDINANCES TO AMEND THE BUILDING CODE OF THE CITY 0F' 8EADMO0I TO PROVIDE REGULATIONS CONCERNING FIRE HYDRANTS AND ACCESS TO BUILDINGS AND ALARM SYSTEMS; PROVIDING FOR SEVBBABILITy; PROVIDING FOR REPEAL AND PROVIDING A PENALTY. BE IT ORDAINED BY THE CITY OF BEADM00I: Section l . That Chapter 6 , Section 6-21 of the Code of ordinances is hereby amended to add new sections 904 and 905 to the I982 Edition of the Standard Building Code to read as follows: Section 904 Eire Hydrants: l . All sites to be built upon shall have adequate fire hydrants, water lines, and tire aooeaa drives according to the type of construction. It shall be the responsibility of the developer to provide such fire hydrants, water lines, and fire access drives as follows: a) Water lines shall be of proper material as specified by City standards and their sizes and fittings shall meet minimum requirements as specified by the City of Beaumont Water Utilities Department. Fire hydrants shall have openings and fittings which fit City of Beaumont Fire Department equipment. b) Fire hydrants shall be accessible for use so that tire trucks with mid-mount steamer connections can be driven over an all-weather surface road or drive to within ten ( IO' ) feet of the fire hydrant. o) Fire hydrants shall be placed not less than two ( 2 ' ) feet nor more than four ( 4 " ) feet from the line edge of street or drive , with a 3-font radios clearance. d) The center of the steamer connection of the fire hydrant shall be not less than twelve ( 12" ) inches nor more than twenty-four ( 24" ) inches above the natural ground level or concrete grade level. e) Dead end water mains which supply fire hydrants shall be permitted only by the Fire Chief and Director of Water Utilities, after a study of the plans for the development and a determination that water mains cannot be looped. t ) During construction, water lines, hydrants and all-weather access drives shall be installed and usable for fire protection in such a manner that dietaoc.ea to buildings specified in 2-b and 2-o below are not exceeded by more than 50% at any point when construction has progressed above foundation level. After initial occupancy no allowance from the distances specified in 2-b and 2-c below will be permitted. 2 . Location of Fire Hydrants: a) Single-family dwelling sites Eire hydrants shall be located along the curb or edge line of a street, public road or private drive so that each. single-family dwelling unitis within 350 feet of a fire hydrant. (This will result in a normal spacing of fire hydrants 700 feet or less measured along the curb or edge line of a street, public road or private drive. ) b) Multi-family dwelling sites ( apartments, townhomes, cluster housing , condominiums , hotels , motels , high-rise apartments or any multi-family dwellings ) Fire hydrants shall be located along the curb or edge line of a street, public road or private drive so that each building is within 300 feet of a fire hydrant. (This will result in a normal spacing of fire hydrants 600 feet or less measured along the curb or edge line of a street, public road or private drive. ) c) Commercial and industrial sites: Fire hydrants shall be located along the curb or edge line of a street, public road, private drive or parking lots so that each building or every portion of a building is within 250 feet of a fire hydrant. (This will result in a normal spacing of fire hydrants 500 feet or less measured along the curb or edge line of a street, public road , private drive or parking lot. ) 3 . Approval a) The complete layout of fire hydrants and water lines shall be submitted to the Fire Chief for approval before installation. 4 . Obstruction of fire hydrants a) No person may stop , park or leave standing any non-emergency vehicle, whether attended or unattended, within 15 feet of a fire hydrant. b) No person may obstruct, in whole or in part, any fire hydrant within the city limits of Beaumont with or by lumber, boxes, merchandise or any material or substance of any kind, character or description. c) No person may obstruct, in whole or in part, any fire hydrant within the City of Beaumont by flowers, shrubs or plants of any description. Section 905 - Control Access to be Provided by Operator or Premises The operator of premises where a building exists or is under construction shall provide the building with horizontal access, each road of which. shall, - 2 - a) be public or private; b) have a width of at least 20 feet; c) have an overhead clearance of at least 14 feet; d) intersects with a dedicated street; e) if longer than 100 feet i ) intersect with a dedicated street at each end; ii) end in a traffic circle having a diameter of at least 50 feet; f ) be free of all obstructions which pose a sub- stantial threat of interference to fire-fighting or rescue activities: g) be surfaced with a material substantial enough to support fire department vehicles; and, h) remain structurally unaffected during inclement weather. Section 2 . That Section 1124 of the 1982 Edition of the Standard Building Code is hereby deleted and repealed and a new section 1124 is hereby enacted in lieu thereof to read as follows: Section 1124: Any building, exceeding 2 ,000 square feet ( except single family dwellings or dwelling units within an apartment house, condominium or townhouse having exterior entrances to each unit) shall be equipped with an automatic fire alarm system in a manner meeting or exceeding the requirements of N. F.P.A. Standard 72E. Fire alarm systems shall be tested in accordance with manufacturer' s recommendations and at least once each year by a licensed fire alarm company . Section 3 . That if any section, subsection, sentence, clause or phrase of this ordinance, or the application of same to a particular set of persons or circumstances, should for any reason be held to be invalid, such invalidity shall not affect the remaining portions of this ordinance, and to such end the various portions and provisions of this ordinance are declared to be severable. Section 4 . All ordinances or parts of ordinances in conflict herewith are repealed to the extent of the conflict only. - 3 - Section 5 . Any person who violates any provision of this ordinance shall, upon conviction, be punished as provided in Section 1-8 of the Code of Ordinances of Beaumont, Texas. PASSED BY THE CITY COUNCIL of the City of Beaumont this the /S,Ck day of 19 d3 . Mayor - 4 -